Serial angiographic and intravascular ultrasound evaluation to interrogate the presence of late “catch-up” phenomenon after cypher® sirolimus-eluting stent implantation

作者: Daniel Chamié , Alexandre Abizaid , J Ribamar Costa , Fausto Feres , J Fábio Almiro da Silva

DOI: 10.1007/S10554-010-9723-Z

关键词:

摘要: Despite the expressive reduction in intimal hyperplasia (IH) formation after DES implantation at mid-term, late restenosis has been recently noticed. Our objective was to determine, by means of serial angiography (QCA) and intravascular ultrasound (IVUS) two different time points, whether occurrence “late catch-up” phenomenon occurs sirolimus-eluting stent (SES) implantation. Thirty-eight non-complex patients treated with a single 18-mm SES who had systematic QCA IVUS analyses mean 8 20 months were enrolled. Primary endpoint is evaluate temporal course IH implantation, comparing in-stent loss percent obstruction between invasive follow-ups. Mean cohort age 59.3 years 31.6% diabetics. Baseline reference vessel diameter 2.8 ± 0.4 mm lesion length 11.5 3.5 mm. Left anterior descending artery most frequent target (55.3%). Between months, non-significant increase from 0.10 0.18 0.15 0.30 (P = 0.38) observed. By IVUS, slight (1.03 2.13 1.76 1.87%, P 0.12) detected evaluations. Interestingly, all neoformed tissue accrued accumulated distal portion stent. In scenario, associated minimal, volume months.

参考文章(26)
F JNeumann, RDietz, ASchömig, GRichardt, AKastrati, Time course of restenosis during the first year after emergency coronary stenting. Circulation. ,(1993)
Giora Weisz, Martin B. Leon, David R. Holmes, Dean J. Kereiakes, Jeffrey J. Popma, Paul S. Teirstein, Sidney A. Cohen, Hong Wang, Donald E. Cutlip, Jeffrey W. Moses, Five-year follow up after sirolimus-eluting stent implantation results of the SIRIUS (Sirolimus-Eluting Stent in De-Novo Native Coronary Lesions) Trial Journal of the American College of Cardiology. ,vol. 53, pp. 1488- 1497 ,(2009) , 10.1016/J.JACC.2009.01.050
Duk-Woo Park, Myeong-Ki Hong, Gary S. Mintz, Cheol Whan Lee, Jong-Min Song, Ki-Hoon Han, Duk-Hyun Kang, Sang-Sig Cheong, Jae-Kwan Song, Jae-Joong Kim, Neil J. Weissman, Seong-Wook Park, Seung-Jung Park, Two-Year Follow-Up of the Quantitative Angiographic and Volumetric Intravascular Ultrasound Analysis After Nonpolymeric Paclitaxel-Eluting Stent Implantation Journal of the American College of Cardiology. ,vol. 48, pp. 2432- 2439 ,(2006) , 10.1016/J.JACC.2006.08.033
Stéphane Cook, Peter Wenaweser, Stephan Windecker, Very late restenosis of a sirolimus-eluting stent after left main coronary artery stenting Canadian Journal of Cardiology. ,vol. 23, pp. 64- 64 ,(2007) , 10.1016/S0828-282X(07)70216-7
Laura Mauri, E John Orav, Richard E Kuntz, None, Late Loss in Lumen Diameter and Binary Restenosis for Drug-Eluting Stent Comparison Circulation. ,vol. 111, pp. 3435- 3442 ,(2005) , 10.1161/CIRCULATIONAHA.104.513952
John Cosgrave, Simon J. Corbett, Gloria Melzi, Rade Babic, Giuseppe G.L. Biondi-Zoccai, Flavio Airoldi, Alaide Chieffo, Giuseppe M. Sangiorgi, Matteo Montorfano, Iassen Michev, Mauro Carlino, Antonio Colombo, Late restenosis following sirolimus-eluting stent implantation. American Journal of Cardiology. ,vol. 100, pp. 41- 44 ,(2007) , 10.1016/J.AMJCARD.2007.01.070
Rainer Wessely, Adnan Kastrati, Albert Schömig, Late restenosis in patients receiving a polymer-coated sirolimus-eluting stent. Annals of Internal Medicine. ,vol. 143, pp. 392- 394 ,(2005) , 10.7326/0003-4819-143-5-200509060-00119
Gregg W. Stone, Stephen G. Ellis, David A. Cox, James Hermiller, Charles O'Shaughnessy, James Tift Mann, Mark Turco, Ronald Caputo, Patrick Bergin, Joel Greenberg, Jeffrey J. Popma, Mary E. Russell, A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease The New England Journal of Medicine. ,vol. 350, pp. 221- 231 ,(2004) , 10.1056/NEJMOA032441
Takeshi Kimura, Hiroyoshi Yokoi, Yoshihisa Nakagawa, Takashi Tamura, Satoshi Kaburagi, Yoshihiro Sawada, Yasukazu Sato, Hiroatsu Yokoi, Naoya Hamasaki, Hideyuki Nosaka, Masakiyo Nobuyoshi, Three-Year Follow-up after Implantation of Metallic Coronary-Artery Stents The New England Journal of Medicine. ,vol. 334, pp. 561- 566 ,(1996) , 10.1056/NEJM199602293340903
Jiro Aoki, Alexandre C. Abizaid, Patrick W. Serruys, Andrew T.L. Ong, Eric Boersma, J. Eduardo Sousa, Nico Bruining, Evaluation of four-year coronary artery response after sirolimus-eluting stent implantation using serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis for plaque composition in event-free patients. Journal of the American College of Cardiology. ,vol. 46, pp. 1670- 1676 ,(2005) , 10.1016/J.JACC.2005.06.076