Carbon Nanotube Based Sensor for Simultaneous Determination of Acetaminophen and Ascorbic Acid Exploiting Multiple Response Optimization and Measures in the Presence of Surfactant

作者: Eduardo Henrique Duarte , Lauro Tatsuo Kubota , César Ricardo Teixeira Tarley

DOI: 10.1002/ELAN.201200426

关键词:

摘要: A simple procedure for the simultaneous determination of acetaminophen (AC) and ascorbic acid (AA) by differential pulse voltammetry (DPV) using a carbon nanotube paste electrode exploiting measures in cetylpyridinium bromide (CPB) medium is described. Under best instrumental parameters DPV, optimized means factorial design, calibration plots range 100.0–700.0 µmol L−1 (r=0.993) 39.4–146.3 µmol L−1 (r=0.995) with limits detection 7.1 2.1 µmol L−1, were achieved AA AC, respectively. The developed method was successfully applied AC pharmaceutical formulations, whose accuracy attested comparison HPLC method.

参考文章(35)
Lourdes Agüí, Paloma Yáñez-Sedeño, José M. Pingarrón, Role of carbon nanotubes in electroanalytical chemistry: A review Analytica Chimica Acta. ,vol. 622, pp. 11- 47 ,(2008) , 10.1016/J.ACA.2008.05.070
Xiao-Gang Wang, Qing-Sheng Wu, Wang-Zhuan Liu, Ya-Ping Ding, Simultaneous determination of dinitrophenol isomers with electrochemical method enhanced by surfactant and their mechanisms research Electrochimica Acta. ,vol. 52, pp. 589- 594 ,(2006) , 10.1016/J.ELECTACTA.2006.05.038
George Derringer, Ronald Suich, Simultaneous Optimization of Several Response Variables Journal of Quality Technology. ,vol. 12, pp. 214- 219 ,(1980) , 10.1080/00224065.1980.11980968
Biuck Habibi, Mojtaba Jahanbakhshi, Mohammad Hossein Pournaghi-Azar, Differential pulse voltammetric simultaneous determination of acetaminophen and ascorbic acid using single-walled carbon nanotube-modified carbon–ceramic electrode Analytical Biochemistry. ,vol. 411, pp. 167- 175 ,(2011) , 10.1016/J.AB.2011.01.005
Nathaniel Havens, Phong Trihn, Daniel Kim, Manelich Luna, Adam K. Wanekaya, Amos Mugweru, Redox polymer covalently modified multiwalled carbon nanotube based sensors for sensitive acetaminophen and ascorbic acid detection Electrochimica Acta. ,vol. 55, pp. 2186- 2190 ,(2010) , 10.1016/J.ELECTACTA.2009.11.054
Sebastian J. Padayatty, Arie Katz, Yaohui Wang, Peter Eck, Oran Kwon, Je-Hyuk Lee, Shenglin Chen, Christopher Corpe, Anand Dutta, Sudhir K Dutta, Mark Levine, Vitamin C as an Antioxidant: Evaluation of Its Role in Disease Prevention Journal of The American College of Nutrition. ,vol. 22, pp. 18- 35 ,(2003) , 10.1080/07315724.2003.10719272
G. L. Long, E. G. Voigtman, M. A. Kosinski, J. D. Winefordner, Reduction of electronic noise in inductively coupled plasma atomic emission and fluorescence spectrometric measurements Analytical Chemistry. ,vol. 55, pp. 1432- 1434 ,(1983) , 10.1021/AC00259A060
Rajendra N. Goyal, Sudhanshu P. Singh, Voltammetric determination of paracetamol at C60-modified glassy carbon electrode Electrochimica Acta. ,vol. 51, pp. 3008- 3012 ,(2006) , 10.1016/J.ELECTACTA.2005.08.036