Nanocomposites consisting of copper and copper oxide incorporated into MoS4 nanostructures for sensitive voltammetric determination of bisphenol A.

作者: Ghazala Ashraf , Muhammad Asif , Ayesha Aziz , Zhengyun Wang , Xiaoyu Qiu

DOI: 10.1007/S00604-019-3406-9

关键词:

摘要: A nanocomposite (NC) of type Cu/Cu2O/CuO@MoS4 was obtained via coprecipitation and a hydrothermal approach from copper oxide nanoparticles MoS4 nanostructures. series nanocomposites has been fabricated with varying fractions MoS4. The NCs were characterized by XRD, XPS, SEM TEM. synergistic effect enlarged specific surface, high electrocatalytic activity the presence mixed valencies strongly enhance redox response at interface a glassy carbon electrode (GCE) modified NC. intercalation properties in result outstanding electro-oxidative performance towards bisphenol (BPA). GCE, best operated +0.16 V vs. SCE, linear 0.0001 μM to 17 μM BPA concentration range (R2 = 0.998) sensitivity (1587 mA μM−1 cm−2). sensor can detect very good selectivity, enhanced storage stability low detection limit 0.10 nM (S/N = 3). This is lowest value among non-enzymatic biosensors reported until now. used for real-time in-vitro monitoring (spiked) serum samples.

参考文章(35)
Muhammad Asif, Ayesha Aziz, Anh Quang Dao, Abdul Hakeem, Haitao Wang, Shuang Dong, Guoan Zhang, Fei Xiao, Hongfang Liu, None, Real-time tracking of hydrogen peroxide secreted by live cells using MnO2 nanoparticles intercalated layered doubled hydroxide nanohybrids. Analytica Chimica Acta. ,vol. 898, pp. 34- 41 ,(2015) , 10.1016/J.ACA.2015.09.053
Ke-Jing Huang, Yu-Jie Liu, Yan-Ming Liu, Ling-Ling Wang, Molybdenum disulfide nanoflower-chitosan-Au nanoparticles composites based electrochemical sensing platform for bisphenol A determination. Journal of Hazardous Materials. ,vol. 276, pp. 207- 215 ,(2014) , 10.1016/J.JHAZMAT.2014.05.037
Honglin Li, Ke Yu, Xiang Lei, Bangjun Guo, Chao Li, Hao Fu, Ziqiang Zhu, Synthesis of the MoS2@CuO heterogeneous structure with improved photocatalysis performance and H2O adsorption analysis. Dalton Transactions. ,vol. 44, pp. 10438- 10447 ,(2015) , 10.1039/C5DT01125F
Peihong Deng, Zhifeng Xu, Junhua Li, Yunfei Kuang, Acetylene black paste electrode modified with a molecularly imprinted chitosan film for the detection of bisphenol A Mikrochimica Acta. ,vol. 180, pp. 861- 869 ,(2013) , 10.1007/S00604-013-1001-Z
Gabor A. Somorjai, Jeong Y. Park, Molecular factors of catalytic selectivity. Angewandte Chemie. ,vol. 47, pp. 9212- 9228 ,(2008) , 10.1002/ANIE.200803181
Kartick Bindumadhavan, Suneel Kumar Srivastava, Sourindra Mahanty, MoS2-MWCNT hybrids as a superior anode in lithium-ion batteries. Chemical Communications. ,vol. 49, pp. 1823- 1825 ,(2013) , 10.1039/C3CC38598A
Haixia Fan, Yan Li, Dan Wu, Hongmin Ma, Kexia Mao, Dawei Fan, Bin Du, He Li, Qin Wei, Electrochemical bisphenol A sensor based on N-doped graphene sheets Analytica Chimica Acta. ,vol. 711, pp. 24- 28 ,(2012) , 10.1016/J.ACA.2011.10.051
Yongsong Luo, Youchao Tu, Qinfeng Ren, Xiaojun Dai, Lanlan Xing, Jialin Li, Surfactant-free fabrication of Cu2O nanosheets from Cu colloids and their tunable optical properties Journal of Solid State Chemistry. ,vol. 182, pp. 182- 186 ,(2009) , 10.1016/J.JSSC.2008.09.027
Yong Gao, Yu Cao, Duanguang Yang, Xujun Luo, Yiming Tang, Huaming Li, Sensitivity and selectivity determination of bisphenol A using SWCNT–CD conjugate modified glassy carbon electrode Journal of Hazardous Materials. ,vol. 199, pp. 111- 118 ,(2012) , 10.1016/J.JHAZMAT.2011.10.066