Optimal turbine spacing in fully developed wind farm boundary layers

作者: Johan Meyers , Charles Meneveau

DOI: 10.1002/WE.469

关键词:

摘要: … power output P * to variations of s around the optimum s opt , we evaluated suboptimal solutions in Figure 5(b). To this end, we define the suboptimal spacing s η (α) as the spacing that …

参考文章(20)
John L. Lumley, Hendrik Tennekes, A First Course in Turbulence ,(1972)
Ervin Bossanyi, Nick Jenkins, Tony Burton, David Sharpe, Wind Energy Handbook ,(2001)
Marc Calaf, Charles Meneveau, Johan Meyers, Large eddy simulation study of fully developed wind-turbine array boundary layers Physics of Fluids. ,vol. 22, pp. 015110- ,(2010) , 10.1063/1.3291077
J. F. Manwell, J. G. McGowan, A. L. Rogers, Wind Energy Explained John Wiley & Sons, Ltd. ,(2009) , 10.1002/9781119994367
Raúl Bayoán Cal, José Lebrón, Luciano Castillo, Hyung Suk Kang, Charles Meneveau, Experimental study of the horizontally averaged flow structure in a model wind-turbine array boundary layer Journal of Renewable and Sustainable Energy. ,vol. 2, pp. 013106- ,(2010) , 10.1063/1.3289735
Sten Frandsen, On the wind speed reduction in the center of large clusters of wind turbines Journal of Wind Engineering and Industrial Aerodynamics. ,vol. 39, pp. 251- 265 ,(1992) , 10.1016/0167-6105(92)90551-K
Stefan Emeis, Sten Frandsen, Reduction of horizontal wind speed in a boundary layer with obstacles Boundary-Layer Meteorology. ,vol. 64, pp. 297- 305 ,(1993) , 10.1007/BF00708968
A Jimenez, A Crespo, E Migoya, J Garcia, Advances in large-eddy simulation of a wind turbine wake Journal of Physics: Conference Series. ,vol. 75, pp. 012041- ,(2007) , 10.1088/1742-6596/75/1/012041