Selective detection of hazardous VOCs for indoor air quality applications using a virtual gas sensor array

作者: M. Leidinger , T. Sauerwald , W. Reimringer , G. Ventura , A. Schütze

DOI: 10.5194/JSSS-3-253-2014

关键词:

摘要: … , linear discriminant analysis is applied to single sensor data and sensor fusion data. … when using the sensor fusion method for combining data of the different MOS sensor types. …

参考文章(21)
, Beurteilung von Innenraumluftkontaminationen mittels Referenz- und Richtwerten Bundesgesundheitsblatt-gesundheitsforschung-gesundheitsschutz. ,vol. 50, pp. 990- 1005 ,(2007) , 10.1007/S00103-007-0290-Y
K. Koistinen, D. Kotzias, S. Kephalopoulos, C. Schlitt, P. Carrer, M. Jantunen, S. Kirchner, J. McLaughlin, L. Mølhave, E. O. Fernandes, B. Seifert, The INDEX project: executive summary of a European Union project on indoor air pollutants. Allergy. ,vol. 63, pp. 810- 819 ,(2008) , 10.1111/J.1398-9995.2008.01740.X
Jonathan A. Bernstein, Neil Alexis, Hyacinth Bacchus, I. Leonard Bernstein, Pat Fritz, Elliot Horner, Ning Li, Stephany Mason, Andre Nel, John Oullette, Kari Reijula, Tina Reponen, James Seltzer, Alisa Smith, Susan M. Tarlo, The health effects of nonindustrial indoor air pollution Journal of Allergy and Clinical Immunology. ,vol. 121, pp. 585- 591 ,(2008) , 10.1016/J.JACI.2007.10.045
Peter Reimann, Andreas Schütze, Fire detection in coal mines based on semiconductor gas sensors Sensor Review. ,vol. 32, pp. 47- 58 ,(2012) , 10.1108/02602281211197143
Otmar Geiss, Georgios Giannopoulos, Salvatore Tirendi, Josefa Barrero-Moreno, Bo R. Larsen, Dimitrios Kotzias, The AIRMEX study - VOC measurements in public buildings and schools/kindergartens in eleven European cities: Statistical analysis of the data Atmospheric Environment. ,vol. 45, pp. 3676- 3684 ,(2011) , 10.1016/J.ATMOSENV.2011.04.037
H. Sagunski, W. Heger, Richtwerte für die Innenraumluft: Naphthalin Bundesgesundheitsblatt-gesundheitsforschung-gesundheitsschutz. ,vol. 47, pp. 705- 712 ,(2004) , 10.1007/S00103-004-0869-5
H Guo, S.C Lee, L.Y Chan, W.M Li, Risk assessment of exposure to volatile organic compounds in different indoor environments Environmental Research. ,vol. 94, pp. 57- 66 ,(2004) , 10.1016/S0013-9351(03)00035-5
Chien-Hou Wu, Chien-Tai Feng, Yu-Shiu Lo, Tsai-Yin Lin, Jiunn-Guang Lo, Determination of volatile organic compounds in workplace air by multisorbent adsorption/thermal desorption-GC/MS Chemosphere. ,vol. 56, pp. 71- 80 ,(2004) , 10.1016/J.CHEMOSPHERE.2004.02.003
M. Leidinger, T. Sauerwald, T. Conrad, W. Reimringer, G. Ventura, A. Schütze, Selective Detection of Hazardous Indoor VOCs Using Metal Oxide Gas Sensors Procedia Engineering. ,vol. 87, pp. 1449- 1452 ,(2014) , 10.1016/J.PROENG.2014.11.722