Wrist pulse gripper system

作者: Faijan Mafat , Bhaskar Thakker

DOI: 10.1109/ICGCIOT.2015.7380531

关键词:

摘要: Wrist pulse signals have been practiced for the health diagnosis in Ancient Indian Medicine Ayurveda and Traditional Chinese Medicine. This simple non-invasive approach describes use of three finger tips acquiring over radial artery around wrist both hands. Several degrees controlled pressure generated by points help practitioner correct diagnosis. paper a prototype gripper mechanism to acquire such supporting generation points. The whole system is with Cortex-M4 architecture microcontroller STM32F429. Mini air-motor pump used inflate cuff, which wrapped wrist. sensor integrated along cuff signals.

参考文章(12)
Bharat S. Shete, A. B. Kakade, PULSE DIAGNOSIS BASED AUTOMATED DIAGNOSTIC SYSTEM ,(2012)
Peng Wang, Wangmeng Zuo, David Zhang, A Compound Pressure Signal Acquisition System for Multichannel Wrist Pulse Signal Analysis IEEE Transactions on Instrumentation and Measurement. ,vol. 63, pp. 1556- 1565 ,(2014) , 10.1109/TIM.2013.2267458
Pei-Yong Zhang, Hui-Yan Wang, A framework for automatic time-domain characteristic parameters extraction of human pulse signals EURASIP Journal on Advances in Signal Processing. ,vol. 2008, pp. 468390- ,(2008) , 10.1155/2008/468390
Yu-Wen Chu, Yu-Feng Chung, Chung-Shing Hu, Ching-Hsing Luo, Cheng-Chang Yeh, Xiao-Chen Si, The Wrist Fixer System of Three Position and Nine Indicators Pulse Diagnosis Instrument 2011 4th International Conference on Biomedical Engineering and Informatics (BMEI). ,vol. 3, pp. 1188- 1191 ,(2011) , 10.1109/BMEI.2011.6098633
Junyoung Lee, The Study on the Intellectual Analysis Algorithm for Oriental Pulse Parameters Journal of Medical Systems. ,vol. 31, pp. 345- 349 ,(2007) , 10.1007/S10916-007-9074-Z
John J. Neumann, David W. Greve, Irving J. Oppenheim, Comparison of piezoresistive and capacitive ultrasonic transducers Smart Structures and Materials 2004: Sensors and Smart Structures Technologies for Civil, Mechanical, and Aerospace Systems. ,vol. 5391, pp. 230- 238 ,(2004) , 10.1117/12.539560
A bhinav, Meghna Sareen, Mahendra Kumar, Jayashree Santhosh, Ashok Salhan, Sneh Anand, Nadi Yantra: a robust system design to capture the signals from the radial artery for assessment of the autonomic nervous system non-invasively Journal of Biomedical Science and Engineering. ,vol. 2, pp. 471- 479 ,(2009) , 10.4236/JBISE.2009.27068
Yinghui Chen, Lei Zhang, David Zhang, Dongyu Zhang, Computerized Wrist Pulse Signal Diagnosis Using Modified Auto-Regressive Models Journal of Medical Systems. ,vol. 35, pp. 321- 328 ,(2011) , 10.1007/S10916-009-9368-4
Stanley Kon, Kenn Oldham, Roberto Horowitz, Piezoresistive and piezoelectric MEMS strain sensors for vibration detection The 14th International Symposium on: Smart Structures and Materials & Nondestructive Evaluation and Health Monitoring. ,vol. 6529, ,(2007) , 10.1117/12.715814
Chu-Chang Tyan, Shing-Hong Liu, Jan-Yow Chen, Jian-Jung Chen, Wen-Miin Liang, A Novel Noninvasive Measurement Technique for Analyzing the Pressure Pulse Waveform of the Radial Artery IEEE Transactions on Biomedical Engineering. ,vol. 55, pp. 288- 297 ,(2008) , 10.1109/TBME.2007.910681