Hemodynamic evaluation of the Carbomedics R, St Jude Medical HP and Sorin-Bicarbon valve in patients with small aortic annulus.

作者: Giorgio Noera , P Pensa , Mauro Lamarra , Roberto Mascagni , Alberto Cremonesi

DOI: 10.1016/S1010-7940(96)01090-1

关键词:

摘要: A Doppler echocardiographic study was performed to evaluate the hemodynamic performance of three 19 mm size currently used bileaflet valve prosthesis (St Jude Medical Hydrodinamic Plus, Sorin-Bicarbon and Carbomedic Reduced) implanted in aortic position. Methods: Patients, 30, with same profile receiving (ten for each type) were selected when body surface area (BSA) > 1.7 m 2 . echocardiography carried out at rest after exercise, 60 days surgery. Peak (Pg) mean (Mg) gradients across recorded: effective orifice (EOA), index (PI) calculated. Results: No significant differences observed between St Sorin Bicarbon as far peak gradient, exercise. difference (P < 0.05) demonstrated above mentioned parameters Carbomedics-R tested. This type showed a lower EOA PI higher Pg Mg gradient both Conclusion: The Hydrodymanic plus (Hp) valves had similar better trend compared patients large areas. shows ineffective use total

参考文章(6)
Dale C. Wortham, Terry B. Tri, Thomas E. Bowen, Hemodynamic evaluation of the St. Jude Medical valve prosthesis in the small aortic anulus The Journal of Thoracic and Cardiovascular Surgery. ,vol. 81, pp. 615- 620 ,(1981) , 10.1016/S0022-5223(19)39496-6
Hartzell V. Schaff, A. Michael Borkon, Clifford Hughes, Stephen Achuff, James S. Donahoo, Timothy J. Gardner, Levi Watkins, Vincent L. Gott, Andrew G. Morrow, Robert K. Brawley, Clinical and Hemodynamic Evaluation of the 19 mm Björk-Shiley Aortic Valve Prosthesis The Annals of Thoracic Surgery. ,vol. 32, pp. 50- 57 ,(1981) , 10.1016/S0003-4975(10)61373-2
Helmut Baumgartner, Steven Khan, Michele DeRobertis, Lawrence Czer, Gerald Maurer, Effect of prosthetic aortic valve design on the Doppler-catheter gradient correlation: An in vitro study of normal St. Jude, Medtronic-Hall, Starr-Edwards and Hancock valves Journal of the American College of Cardiology. ,vol. 19, pp. 324- 332 ,(1992) , 10.1016/0735-1097(92)90486-7
Halfdan Ihlen, Per Mølstad, Svein Simonsen, Karleif Vatne, Eivind Øvrum, Odd Geiran, Petter Laake, Tor Frøysaker, Hemodynamic evaluation of the CarboMedics prosthetic heart valve in the aortic position: comparison of noninvasive and invasive techniques. American Heart Journal. ,vol. 123, pp. 151- 159 ,(1992) , 10.1016/0002-8703(92)90759-O
Ellis L. Jones, Joseph M. Craver, Douglas C. Morris, Spencer B. King, John S. Douglas, Robert H. Franch, Charles R. Hatcher, E. Allen Morgan, Hemodynamic and clinical evaluation of the Hancock xenograft bioprosthesis for aortic valve replacement (with emphasis on management of the small aortic root) The Journal of Thoracic and Cardiovascular Surgery. ,vol. 75, pp. 300- 308 ,(1978) , 10.1016/S0022-5223(19)41304-4