Simple system for part-per-billion-level volatile organic compound analysis in groundwater and urban air

作者: Ljiubov Morris , Daren J Caruana , David E Williams

DOI: 10.1088/0957-0233/13/4/325

关键词:

摘要: A simple device is described, capable of measuring reliably and reproducibly low levels (0.1 ppbv with a total analysis time approximately 40 min) volatile organic compounds (VOCs) in urban air the headspace groundwater. The VOCs were pre-concentrated onto small bed Tenax TA®, subsequently released by temperature-programmed thermal desorption (TPD). TPD profiles recorded solid-state sensor array. success method was based on well defined peak shape if absorbent sufficiently thin, linearity additivity appropriately transformed signals, use very stable array utilizing chromium-titanium oxide as material devices different electrode gaps dry carrier gas. Successful groundwater achieved diluting sample stream 1:4 (which prevented saturation adsorbent surface water) introducing purge at room temperature before removed excess water from hence stabilized baseline desorption). Principal components spectral decomposition (SD) methods used successfully for identification quantification mixtures. SD expressed measured trace elements sum number spectra. individual traces each characteristic spectrum thus derived could be further resolved fitting procedure because had form, which both width correlated boiling VOCs, varied according to functional type: phenols>aliphatics>alkyl-substituted benzenes.

参考文章(24)
I Heberle, A Liebminger, U Weimar, W Göpel, Optimised sensor arrays with chromatographic preseparation: characterisation of alcoholic beverages Sensors and Actuators B-chemical. ,vol. 68, pp. 53- 57 ,(2000) , 10.1016/S0925-4005(00)00461-5
Chaohua Feng, Somenath Mitra, Two-stage microtrap as an injection device for continuous on-line gas chromatographic monitoring Journal of Chromatography A. ,vol. 805, pp. 169- 176 ,(1998) , 10.1016/S0021-9673(98)00041-7
A. K. Smilde, R. Tauler, J. M. Henshaw, L. W. Burgess, B. R. Kowalski, Multicomponent Determination of Chlorinated Hydrocarbons Using a Reaction-Based Chemical Sensor. 3. Medium-Rank Second-Order Calibration with Restricted Tucker Models Analytical Chemistry. ,vol. 66, pp. 3345- 3351 ,(1994) , 10.1021/AC00092A010
Chia-Jung Lu, Edward T. Zellers, A dual-adsorbent preconcentrator for a portable indoor-VOC microsensor system. Analytical Chemistry. ,vol. 73, pp. 3449- 3457 ,(2001) , 10.1021/AC001524K
Chiung-Yu Peng, Stuart Batterman, Performance evaluation of a sorbent tube sampling method using short path thermal desorption for volatile organic compounds Journal of Environmental Monitoring. ,vol. 2, pp. 313- 324 ,(2000) , 10.1039/B003385P
Detlev Helmig, Air analysis by gas chromatography Journal of Chromatography A. ,vol. 843, pp. 129- 146 ,(1999) , 10.1016/S0021-9673(99)00173-9
David E. Williams, Keith F. E. Pratt, Theory of self-diagnostic sensor array devices using gas-sensitive resistors Journal of the Chemical Society, Faraday Transactions. ,vol. 91, pp. 1961- 1966 ,(1995) , 10.1039/FT9959101961
Janusz Gawłowski, Tomasz Gierczak, Elżbieta Pietruszyñska, Małgorzata Gawryś, Jan Niedzielski, Dry purge for the removal of water from the solid sorbents used to sample volatile organic compounds from the atmospheric air Analyst. ,vol. 125, pp. 2112- 2117 ,(2000) , 10.1039/B004678G
David E. Williams, Keith F. E. Pratt, Resolving combustible gas mixtures using gas sensitive resistors with arrays of electrodes Journal of the Chemical Society, Faraday Transactions. ,vol. 92, pp. 4497- 4504 ,(1996) , 10.1039/FT9969204497