Biomimetic sensor based on molecularly imprinted polymer with nitroreductase-like activity for metronidazole detection.

作者: Yue Gu , Xiaoyi Yan , Cong Li , Bo Zheng , Yaru Li

DOI: 10.1016/J.BIOS.2015.09.060

关键词:

摘要: The utility of molecularly imprinted polymer (MIP) as electrochemical sensor often suffers from its limited catalytic efficiency. Here, we proposed an alternative approach by combining the concept MIP with use mimetic enzyme. A metronidazole nitroreductase-like activity was successfully achieved via method, where melamine served two purposes: functional monomer and component During imprinting process, redox-active center, which is responsible for catalysis, introduced into cavities. Accordingly, polymer, having both catalysis centers recognition sites, exhibited enhanced electrocatalytic selectivity. sensing performances this biomimetic were evaluated in detail. Results revealed that response to linear concentration range 0.5-1000 μM, detection limit 0.12 μM (S/N=3). In addition, applied detect injection solution results implied feasibility practical application.

参考文章(43)
Daming Feng, Zhengmao Zhou, Meiping Bo, An investigation of the thermal degradation of melamine phosphonite by XPS and thermal analysis techniques Polymer Degradation and Stability. ,vol. 50, pp. 65- 70 ,(1995) , 10.1016/0141-3910(95)00123-4
Xiaohua Jiang, Xiangqin Lin, Voltammetry of the interaction of metronidazole with DNA and its analytical applications Bioelectrochemistry. ,vol. 68, pp. 206- 212 ,(2006) , 10.1016/J.BIOELECHEM.2005.08.003
Abdollah Salimi, Mohadeseh Izadi, Rahman Hallaj, Manochehr Rashidi, Simultaneous Determination of Ranitidine and Metronidazole at Glassy Carbon Electrode Modified with Single Wall Carbon Nanotubes Electroanalysis. ,vol. 19, pp. 1668- 1676 ,(2007) , 10.1002/ELAN.200703911
Ralph A Kamin, George S Wilson, None, Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer Analytical Chemistry. ,vol. 52, pp. 1198- 1205 ,(1980) , 10.1021/AC50058A010
De Wang, Ning Gan, Huairong Zhang, Tianhua Li, Li Qiao, Yuting Cao, Xiurong Su, Shan Jiang, Simultaneous electrochemical immunoassay using graphene–Au grafted recombinant apoferritin-encoded metallic labels as signal tags and dual-template magnetic molecular imprinted polymer as capture probes Biosensors and Bioelectronics. ,vol. 65, pp. 78- 82 ,(2015) , 10.1016/J.BIOS.2014.09.085
Xiao Liu, Liqiang Luo, Yaping Ding, Qingsheng Wu, Youli Wei, Daixin Ye, A highly sensitive method for determination of guanine, adenine and epinephrine using poly-melamine film modified glassy carbon electrode Journal of Electroanalytical Chemistry. ,vol. 675, pp. 47- 53 ,(2012) , 10.1016/J.JELECHEM.2012.04.026
Lei Kong, Xiaoying Jiang, Yanbo Zeng, Tianshu Zhou, Guoyue Shi, Molecularly imprinted sensor based on electropolmerized poly(o-phenylenediamine) membranes at reduced graphene oxide modified electrode for imidacloprid determination Sensors and Actuators B-chemical. ,vol. 185, pp. 424- 431 ,(2013) , 10.1016/J.SNB.2013.05.033