Comparative studies of neodymium (III)-selective PVC membrane sensors.

作者: Vinod K. Gupta , Rajendra N. Goyal , Ram A. Sharma

DOI: 10.1016/J.ACA.2009.05.031

关键词:

摘要: Abstract Sensors based on two neutral ionophores, N,N′-bis((1H-pyrrol-2-yl)methylene)cyclohexane-1,2-diamine ( L 1 ) and 3,3′-(cyclohexane-1,2-diylbis(azan-1-yl-1-ylidene)bis(methan-1-yl-1-ylidene)bis(5-hydroxymethyl)pyridine-2-ol) 2 are described for quantification of neodymium (III). Effect various plasticizers; 2-nitrophenyloctylether o -NPOE), dibutyl butylphosphonate (DBBP), tri-n-butyl phosphates (TBP), dioctylpthalate (DOP) chloronapthalen (CN) anion excluder, sodiumtetraphenylborate (NaTPB) has been studied. The membrane composition PVC: -NPOE:ionophore ):NaTPB (w/w; mg) 150:300:5:5 exhibited best performance. sensor with ionophore exhibits significantly enhanced selectivity towards (III) in the concentration range 5.0 × 10 −7 to 1.0 × 10 −2  M a detection limit Nernstian compliance (19.8 ± 0.3 mV decade −1 activity) within pH 4.0–8.0. response time was found as 10 s. influence possible interfering ions also investigated properties electrode. fast stable response, good reproducibility long-term stability observed. work satisfactorily partially non-aqueous media up 20% (v/v) content methanol, ethanol or acetonitrile could be used period 3 months. coefficients determined by using fixed interference method (FIM) indicate high neodymium. proposed electrode shows fairly discrimination from other cations. application prepared demonstrated determination spiked water samples.

参考文章(35)
G. I. Ramendik, E. V. Fatyushina, A. I. Stepanov, Determination of Neodymium and Ytterbium by Isotope Dilution Laser Mass Spectrometry Journal of Analytical Chemistry. ,vol. 58, pp. 152- 155 ,(2003) , 10.1023/A:1022358105429
Mojtaba Shamsipur, Morteza Hosseini, Kamal Alizadeh, Mir Fazlollah Mousavi, Alessandra Garau, Vito Lippolis, Abdollah Yari, PVC Membrane Potentiometric Sensor Based on 5-Pyridino-2,8-dithia[9](2,9)-1,10-phenanthroline- phane for Selective Determination of Neodymium(III) Analytical Chemistry. ,vol. 77, pp. 276- 283 ,(2005) , 10.1021/AC049349L
Alessia Bacchi, Mauro Carcelli, Laura Gabba, Sandra Ianelli, Paolo Pelagatti, Giancarlo Pelizzi, Dominga Rogolino, Syntheses, characterization and X-ray structure of palladium(II) and nickel(II) complexes of tetradentate pyrrole containing ligands Inorganica Chimica Acta. ,vol. 342, pp. 229- 235 ,(2003) , 10.1016/S0020-1693(02)01077-0
J. J. Croat, Current status and future outlook for bonded neodymium permanent magnets (invited) Journal of Applied Physics. ,vol. 81, pp. 4804- 4809 ,(1997) , 10.1063/1.365469
Martin Telting-Diaz, Eric Bakker, Effect of Lipophilic Ion-Exchanger Leaching on the Detection Limit of Carrier-Based Ion-Selective Electrodes Analytical Chemistry. ,vol. 73, pp. 5582- 5589 ,(2001) , 10.1021/AC010526H
Nahid Tavakkoli, Mojtaba Shamsipur, Lead-Selective Membrane Electrode Based on Dibenzopyrydino-18-Crown-6 Analytical Letters. ,vol. 29, pp. 2269- 2279 ,(1996) , 10.1080/00032719608002251
Rudolf Eugster, Thomas Rosatzin, Bruno Rusterholz, Barbara Aebersold, Urs Pedrazza, Denise Rüegg, Angela Schmid, Ursula E. Spichiger, Wilhelm Simon, Plasticizers for liquid polymeric membranes of ion-selective chemical sensors Analytica Chimica Acta. ,vol. 289, pp. 1- 13 ,(1994) , 10.1016/0003-2670(94)80001-4