Validation of a low-dose hybrid RSA and fluoroscopy technique: Determination of accuracy, bias and precision.

作者: James Ioppolo , Niclas Börlin , Charles Bragdon , Mingguo Li , Roger Price

DOI: 10.1016/J.JBIOMECH.2006.01.012

关键词:

摘要: Analyzing skeletal kinematics with radiostereometric analysis (RSA) following corrective orthopedic surgery allows the quantitative comparison of different implant designs. The purpose this stud ...

参考文章(18)
Niclas Börlin, Jerry Eriksson, Per Lindström, A globally convergent gauss-newton algorithm for the bundle adjustment problem with functional constraints Optical 3-D measurement techniques : applications in GIS, mapping, manifactoring, quality control, robotics, navigation, mobile mapping, medical imaging, VR generation and animation. ,vol. 2, pp. 269- 276 ,(2003)
Gilbert W. Beebe, Ionizing radiation and health. American Scientist. ,vol. 70, pp. 35- 44 ,(1982)
Håkan Jonsson, Johan Kärrholm, Three-dimensional knee kinematics and stability in patients with a posterior cruciate ligament tear. Journal of Orthopaedic Research. ,vol. 17, pp. 185- 191 ,(1999) , 10.1002/JOR.1100170206
PIETER M. J. VAN DER ZWET, DOLF J. H. MEYER, JOHAN H. C. REIBER, Automated and accurate assessment of the distribution, magnitude, and direction of pincushion distortion in angiographic images. Investigative Radiology. ,vol. 30, pp. 204- 213 ,(1995) , 10.1097/00004424-199504000-00002
William A. Hoff, Richard D. Komistek, Douglas A. Dennis, Stefan M. Gabriel, Scott A. Walker, Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy. Clinical Biomechanics. ,vol. 13, pp. 455- 472 ,(1998) , 10.1016/S0268-0033(98)00009-6
Thomas SY Tang, NJ MacIntyre, HS Gill, RA Fellows, NA Hill, DR Wilson, Randy E Ellis, Accurate assessment of patellar tracking using fiducial and intensity-based fluoroscopic techniques Medical Image Analysis. ,vol. 8, pp. 343- 351 ,(2004) , 10.1016/J.MEDIA.2004.06.011
Silvia Fantozzi, Angelo Cappello, Alberto Leardini, A global method based on thin-plate splines for correction of geometric distortion: an application to fluoroscopic images. Medical Physics. ,vol. 30, pp. 124- 131 ,(2003) , 10.1118/1.1538228
Niclas Börlin, Comparison of resection–intersection algorithms and projection geometries in radiostereometry Isprs Journal of Photogrammetry and Remote Sensing. ,vol. 56, pp. 390- 400 ,(2002) , 10.1016/S0924-2716(02)00068-0
Charles R. Bragdon, Daniel M. Estok, Henrik Malchau, Johan Kärrholm, Xunhua Yuan, Robert Bourne, Jean Veldhoven, William H. Harris, Comparison of two digital radiostereometric analysis methods in the determination of femoral head penetration in a total hip replacement phantom Journal of Orthopaedic Research. ,vol. 22, pp. 659- 664 ,(2004) , 10.1016/J.ORTHRES.2003.09.004
Eric H. Garling, Bart L. Kaptein, Koos Geleijns, Rob G.H.H. Nelissen, Edward R. Valstar, Marker Configuration Model-Based Roentgen Fluoroscopic Analysis Journal of Biomechanics. ,vol. 38, pp. 893- 901 ,(2005) , 10.1016/J.JBIOMECH.2004.04.026