摘要: To obtain high performance control of a dc-dc converter, good model the converter is needed. It suitable to consider load be included in since it usually affects dynamics. The often most variable part this system. If current and output voltage are measured there possibilities on-line. Adaptive can then applied improve control. In peak current-mode control, inductor utilized by controller. This thesis analyses some properties that obtained if also for Accurate expressions control-to-output transfer function, impedance, audio susceptibility derived buck, boost, buck-boost converters operated continuous conduction mode case where linear resistor. properly controller, impedance becomes low function almost invariant different loads. use acts as feedforward term source. However, resistor influenced changes stability affected. Therefore, not action case. Instead seen gain scheduling, which considered special adaptive shown two published models currentmode Ridley (1991) Tan Middlebrook (1995), give accurate but susceptibility. A novel presented used models. Most results validated comparing frequency responses predicted switched large-signal simulation (Less)

参考文章(30)
R. D. Middlebrook, Slobodan Cuk, A general unified approach to modelling switching-converter power stages power electronics specialists conference. pp. 18- 34 ,(1976) , 10.1109/PESC.1976.7072895
R. Tymerski, Application of the time varying transfer function for exact small-signal analysis power electronics specialists conference. ,vol. 9, pp. 196- 205 ,(1991) , 10.1109/63.286812
M. Clique, A. Fossard, A General Model for Switching Converters IEEE Transactions on Aerospace and Electronic Systems. ,vol. 13, pp. 397- 400 ,(1977) , 10.1109/TAES.1977.308476
R. Tymerski, D. Li, State space models for current programmed pulse width modulated converters power electronics specialists conference. ,vol. 8, pp. 271- 278 ,(1992) , 10.1109/63.233283
B. Johansson, A comparison and an improvement of two continuous-time models for current-mode control international telecommunications energy conference. pp. 552- 559 ,(2002) , 10.1109/INTLEC.2002.1048711
B. Johansson, M. Lenells, Possibilities of obtaining small-signal models of DC-to-DC power converters by means of system identification international telecommunications energy conference. pp. 65- 75 ,(2000) , 10.1109/INTLEC.2000.884229
F.D. Tan, R.D. Middlebrook, A unified model for current-programmed converters IEEE Transactions on Power Electronics. ,vol. 10, pp. 397- 408 ,(1995) , 10.1109/63.391937
Yen-Wu Lo, R.J. King, Sampled-data modeling of the average-input current-mode-controlled buck converter IEEE Transactions on Power Electronics. ,vol. 14, pp. 918- 927 ,(1999) , 10.1109/63.788497
R.B. Ridley, A new, continuous-time model for current-mode control (power convertors) IEEE Transactions on Power Electronics. ,vol. 6, pp. 271- 280 ,(1991) , 10.1109/63.76813