Liquid Mixture Excess Volumes and Total Vapor Pressures Using a Magnetic Suspension Densimeter with Compositions Determined by Chromatographic Analysis: Methane Plus Ethane

作者: M. J. Hiza , W. M. Haynes

DOI: 10.1007/978-1-4613-4039-3_73

关键词:

摘要: The measurements discussed in this paper are part of a comprehensive experimental program to obtain orthobaric liquid densities for the major components LNG and their mixtures using magnetic suspension densimeter. present on methane plus ethane were made evaluate vapor recirculation as method mixing consistency liquid-phase compositions determined by analysis samples. results demonstrate feasibility densimeter accurate isothermal phase equilibria density data simultaneously, with chromatographic analysis.

参考文章(6)
M.J. Hiza, W.M. Haynes, W.R. Parrish, Orthobaric liquid densities and excess volumes for binary mixtures of low molarmass alkanes and nitrogen between 105 and 140 K The Journal of Chemical Thermodynamics. ,vol. 9, pp. 873- 896 ,(1977) , 10.1016/0021-9614(77)90173-2
A.J Kidnay, M.J Hiza, R.C Miller, Liquid—vapour equilibria research on systems of interest in cryogenics — a survey Cryogenics. ,vol. 13, pp. 575- 599 ,(1973) , 10.1016/0011-2275(73)90112-4
W. M. Haynes, Simplified magnetic suspension densimeter for absolute density measurements Review of Scientific Instruments. ,vol. 48, pp. 39- 41 ,(1977) , 10.1063/1.1134846
W.M. Haynes, M.J. Hiza, Measurements of the orthobaric liquid densities of methane, ethane, propane, isobutane, and normal butane The Journal of Chemical Thermodynamics. ,vol. 9, pp. 179- 187 ,(1977) , 10.1016/0021-9614(77)90083-0
W. M. Haynes, M. J. Hiza, N. V. Frederick, Magnetic suspension densimeter for measurements on fluids of cryogenic interest Review of Scientific Instruments. ,vol. 47, pp. 1237- 1250 ,(1976) , 10.1063/1.1134519
M. J. Hiza, A. G. Duncan, A Simple Gas Recirculation Pump for Low Flow and High Pressure Applications Review of Scientific Instruments. ,vol. 40, pp. 513- 514 ,(1969) , 10.1063/1.1683994