Sparing the Hippocampus in Prophylactic Cranial Irradiation Using Three Different Linear Accelerators: A Comparative Study

作者: Georgios Giakoumettis , Areti Gkantaifi , Dimitrios Giakoumettis , Emmanouil Papanastasiou , Georgios Plataniotis

DOI:

关键词:

摘要: Hippocampus protection, as an organ at risk in brain radiotherapy, might protect patients' quality of life. Prophylactic cranial irradiation (PCI) has been used traditionally in small cell lung cancer (SCLC) patients as it increases survival. This study aimed to discover the contributing parameters for a successful PCI with simultaneous protection of the hippocampus by using three different treatment machines. For this purpose, treatment plans were generated for 45 SCLC patients using three half-arcs in three linear accelerators (LINACs; Elekta Infinity, Synergy, and Axesse; Elekta Ltd, Stockholm, Sweden) with different radiation field sizes and multileaf collimator (MLC) leaf thickness characteristics. The prescribed dose was 25 Gy in 10 fractions. Thresholds for the hippocampus were calculated based on the Radiation Therapy Oncology Group 0933 dose constraints. The planning and treatment system templates were …

参考文章(0)