UNICOMPARTMENTAL KNEE REPLACEMENT – DOES BEARING CONGRUENCY MATTER? A FINITE ELEMENT STUDY.

DJ Beard , DW Murray , HS Gill , AJ Price
Orthopaedic Proceedings 414 -414

2009
DEVELOPING AND VALIDATING A UNICOMPARTMENTAL KNEE REPLACEMENT MODEL

H Gray , HS Gill , DW Murray , DJ Beard
Orthopaedic Proceedings 414 -414

2009
RADIOLUCENCY FOLLOWING THE OXFORD UNICOMPARTMENTAL KNEE ARTHROPLASTY: ASSOCIATIVE FACTORS AND EFFECTS ON OUTCOME SCORES

D J Beard , D W Murray , H S Gill , C A F Dodd
Orthopaedic Proceedings 421 -421

2009
EXPERIMENTALLY VALIDATED FINITE ELEMENT MODEL OF A HUMAN TIBIA WITH A UNICOMPARTMENTAL KNEE REPLACEMENT

A. Zavatsky , L. Cristofolini , H.S. Gill , H. Gray
Orthopaedic Proceedings 30 -30

2009
RADIOLUCENCY & CLINICAL OUTCOME FOLLOWING THE OXFORD UNICOMPARTMENTAL KNEE ARTHROPLASTY

H. Gill , C. Dodd , D. Murray , H. Pandit
Orthopaedic Proceedings 318 -318

2010
Validated finite element model of a composite tibia

A. Zavatsky , Luca Cristofolini , H. Gill , H. Gray
20TH I.S.B. CONGRESS

2005
The incidence of physiological radiolucency following Oxford unicompartmental knee replacement and its relationship to outcome.

A. Gulati , R. Chau , H. G. Pandit , H. Gray
Journal of Bone and Joint Surgery-british Volume 91 ( 7) 896 -902

97
2009
The effect of bearing congruency, thickness and alignment on the stresses in unicompartmental knee replacements

D.J. Simpson , H. Gray , D. D’Lima , D.W. Murray
Clinical Biomechanics 23 ( 9) 1148 -1157

56
2008
Effect of modular neck variation on bone and cement mantle mechanics around a total hip arthroplasty stem.

D.J. Simpson , J.P. Little , H. Gray , D.W. Murray
Clinical Biomechanics 24 ( 3) 274 -285

14
2009
Experimentally validated finite element model of a human tibia

H. Gray , A. Zavatsky , L. Cristofolini , H. Gill
Journal of Biomechanics 39

2006
FE ANALYSIS OF FULLY CONGRUENT, POLYRADIAL & FLAT UKR BEARINGS DURING AN ENTIRE STEP-UP ACTIVITY

D.J. Simpson , H. Gray , D.W. Murray , H.S. Gill
Journal of Biomechanics 41

2008
13
2014
Experimental validation of a finite element model of a composite tibia.

H A Gray , A B Zavatsky , F Taddei , L Cristofolini
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 221 ( 3) 315 -324

24
2007
Finite Element Analysis of the Human Tibia

Hans Anthony Gray
University of Oxford

4
2007
Measurement of 3D Dynamic Joint Motion Using Biplane Videoradiography

Hans Anthony Gray , Shanyuanye Guan , Peter Loan , Marcus G. Pandy
Springer International Publishing 1 -15

2
2017
Patent application number: WO2017027905; Imaging method and system

Marcus G. Pandy , Guan Shanyuanye , Farzad Keynejad , Hans Anthony Gray

2017
Six-Degree-of-Freedom Tibiofemoral and Patellofemoral Joint Motion During Activities of Daily Living.

Lucas Thomeer , Shanyuanye Guan , Hans Gray , Anthony Schache
Annals of Biomedical Engineering 49 ( 4) 1183 -1198

1