Mesurement of noise-evoked blood pressure by means of averaging method: Relation between blood pressure rise and SPL

作者: C.-J. Chen , K. Hiramatsu , T. Ooue , K. Takagi , T. Yamamoto

DOI: 10.1016/0022-460X(91)90535-R

关键词: Continuous measurementPhysicsSignalMeasurement deviceNoiseWhite noiseBlood pressureAcousticsSound pressureBlood pressure rise

摘要: Abstract Continuous measurement of systolic blood pressure is carried out while white noise presented repeatedly to the subjects, and signal output device stored in computer. It has been found that rise owing sound presentation clearly shown by synchronized averaging signal. The present authors refer this as noise-evoked pressure. results experiments using stimulus, with levels (SPLs) from 60 100 dB, indicate evoked reaches its peak at about 10 s after onset noise, then gradually falls off. proportional SPL 8·8 mmHg for dB noise.

参考文章(34)
Andrén L, Cardiovascular effects of noise. Acta Medica Scandinavica. ,vol. 657, pp. 1- 45 ,(1982)
Annemarie S. Welch, Bruce L. Welch, Physiological Effects of Noise ,(1970)
J. H. Roberts, R. E. M. Lees, Noise-induced hearing loss and blood pressure Canadian Medical Association Journal. ,vol. 120, pp. 1082- 1084 ,(1979)
MARK YELDERMAN, ALLEN K. REAM, Indirect Measurement of Mean Blood Pressure in the Anesthetized Patient Anesthesiology. ,vol. 50, pp. 253- 255 ,(1979) , 10.1097/00000542-197903000-00022
R. Bartsch, C. Br�ckner, H. G. Dieroff, Influence of different kinds of noise on the ear and some physiological and psychological parameters. International Archives of Occupational and Environmental Health. ,vol. 58, pp. 217- 226 ,(1986) , 10.1007/BF00432104
Stefano Belli, Luciano Sani, Giorgina Scarficcia, Raffaela Sorrentino, Arterial hypertension and noise: A cross-sectional study American Journal of Industrial Medicine. ,vol. 6, pp. 59- 65 ,(1984) , 10.1002/AJIM.4700060109
Trong-Neng Wu, Ying-Chin Ko, Po-Ya Chang, Study of noise exposure and high blood pressure in shipyard workers American Journal of Industrial Medicine. ,vol. 12, pp. 431- 438 ,(1987) , 10.1002/AJIM.4700120408
Daryoush Parvizpoor, Noise Exposure and Prevalence of High Blood Pressure Among Weavers in Iran Journal of Occupational and Environmental Medicine. ,vol. 18, pp. 730- 731 ,(1976) , 10.1097/00043764-197611000-00007
L. A. Geddes, M. Voelz, S. James, D. Reiner, Pulse arrival time as a method of obtaining systolic and diastolic blood pressure indirectly Medical & Biological Engineering & Computing. ,vol. 19, pp. 671- 672 ,(1981) , 10.1007/BF02442787