作者: L. Liu , B.J. Xiao , D.A. Humphreys , Z.P. Luo , S.L. Chen
DOI: 10.1016/J.FUSENGDES.2014.02.069
关键词: Plasma 、 Electromagnetic coil 、 Power (physics) 、 Upgrade 、 Vertical control 、 Controllability 、 Geology 、 Vertical displacement 、 Instability 、 Structural engineering
摘要: Abstract In order to enhance control speed, each up/down Cu passive plate in EAST is cut into 8 pieces. These discontinuous segments are still connected the inner vacuum vessel by steel supporting legs. A model of this segments-vessel-supporting leg loop developed and verified vertical displacement event (VDE) experiments. The internal coil (IC) power supply requirements for VDE also evaluated. particularly, we investigate efficacy location minimize capability. IC upgrade optimized actual discussed. experiments evaluate maximum controllable (dZmax) were done with varying elongation resulting controllability estimates summarized here. experimental results previous simulation that present capacity cannot provide robust control.