Gamma spectrum analysis including NAA with SAMPO for windows

作者: P. A. Aarnio , M. T. Nikkinen , J. T. Routti

DOI: 10.1007/BF02041932

关键词: Analytical chemistryComputer scienceHigh resolutionPattern recognitionArtificial intelligenceUser definedNeutron activation analysisGamma ray spectrometrySoftwareSpectrum analysis

摘要: SAMPO for Windows is a high performance gamma spectrum analysis program. All the measurement, and NAA phases can be done either under full interactive user control or defined tasks used automated measurement sequences including of MCAs sample changers. High resolution gamma-ray spectroscopy together with possibility to resolve complex multiplets accuracy makesSAMPO very suitable INAA. On other hand, automate allows its use effectively also in all routine measurements.

参考文章(15)
P. A. Aarnio, M. T. Nikkinen, J. T. Routti, SAMPO 90 High resolution interactive gamma-spectrum analysis including automation with macros Journal of Radioanalytical and Nuclear Chemistry. ,vol. 160, pp. 289- 295 ,(1992) , 10.1007/BF02041678
Richard B. Firestone, Virginia S. Shirley, Table of isotopes ,(1978)
Markku J. Koskelo, Mark T. Mercier, Verification of gamma spectroscopy programs: a standardized approach Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment. ,vol. 299, pp. 318- 321 ,(1990) , 10.1016/0168-9002(90)90799-C
P. A. Aarnio, J. J. Ala-Heikkilä, T. T. Hakulinen, J. T. Routti, Expert system for nuclide identification in gamma spectrum analysis Journal of Radioanalytical and Nuclear Chemistry. ,vol. 193, pp. 219- 227 ,(1995) , 10.1007/BF02039878
Pertti A. Aarnio, Markku J. Koskelo, Peter Zombori, A new method for the determination of goodness-of-fit in gamma spectroscopy Nuclear Instruments and Methods. ,vol. 184, pp. 487- 492 ,(1981) , 10.1016/0029-554X(81)90751-5
P. A. Aarnio, J. T. Routti, J. V. Sandberg, MicroSAMPO PERSONAL COMPUTER BASED ADVANCED GAMMA SPECTRUM ANALYSIS SYSTEM Journal of Radioanalytical and Nuclear Chemistry. ,vol. 124, pp. 457- 465 ,(1988) , 10.1007/BF02041336
J.T. Routti, S.G. Prussin, Photopeak method for the computer analysis of gamma-ray spectra from semiconductor detectors Nuclear Instruments and Methods. ,vol. 72, pp. 125- 142 ,(1969) , 10.1016/0029-554X(69)90148-7
Leif Højslet Christensen, Kaj Heydorn, Quality assurance of fluorescence peak intensities in EDXRF analysis of environmental samples Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment. ,vol. 299, pp. 562- 566 ,(1990) , 10.1016/0168-9002(90)90844-V