Novel printed electrode immunosensors for Schistosoma japonicum.

作者: Qimei Feng , Shiping Wang , Shuju Zhang , Yunfei Zhou , Huihui Yang

DOI: 10.3969/J.ISSN.1672-7347.2012.06.001

关键词: ChromatographySilver chlorideChemistryWorking electrodeLinear rangeCyclic voltammetrySchistosoma japonicumAntibody titerDifferential pulse voltammetryImmunologySilver chloride electrode

摘要: Objective: To improve the sensitivity and linear range of electrochemical immunosensor to detect Schistosoma japonicum (S. japonicum) antibody. Methods: Carbon inks silver/silver chloride were printed on a polyethylene terephthalate (PET) board make two-electrode test strip, where carbon was working electrode S. soluble egg antigen (SEA) fixed at one end by different methods; silver/ silver used as control. We tested valency antibody cyclic voltammetry (CV) differential pulse (DPV) in an electrochemistry workstation, conducted comparison with results ELISA. Two new immunosensing electrodes have been developed, based glutaraldehyde cross-linked (GA) or chitosan-glutaraldehyde (Chit-GA) transducer fixing antigen. titer means CV DPV. Results: Our experimental (50 μg/L) is optimal concentration for GA sensor, 10 μg/L Chit-GA sensors. The immune reaction time both all essentially complete 1 minute. human positive serum sample detection 1:1000 1:400, 1:500. As dilution ratio increased, value DPV increased proportionally. Conclusion: sensor sensors high broad response, exhibited good relationship between signal titer.

参考文章(8)
E. A. Merkovich, M.-L. Carruette, V. G. Babak, G. A. Vikhoreva, L. S. Gal'braikh, V. E. Kim, Kinetics of the initial stage of gelation in chitosan solutions containing glutaric aldehyde : Viscometric study Colloid Journal. ,vol. 63, pp. 350- 354 ,(2001) , 10.1023/A:1016608630105
Qing-Qing Qiu, Paul Ducheyne, Portonovo S. Ayyaswamy, New bioactive, degradable composite microspheres as tissue engineering substrates. Journal of Biomedical Materials Research. ,vol. 52, pp. 66- 76 ,(2000) , 10.1002/1097-4636(200010)52:1<66::AID-JBM9>3.0.CO;2-2
J. P. Hart, S. Serban, L. J. Jones, N. Biddle, R. Pittson, G. A. Drago, Selective and Rapid Biosensor Integrated into a Commercial Hand‐Held Instrument for the Measurement of Ammonium Ion in Sewage Effluent Analytical Letters. ,vol. 39, pp. 1657- 1667 ,(2006) , 10.1080/00032710600713545
D.R. Matthews, E. Bown, A. Watson, R.R. Holman, J. Steemson, S. Hughes, D. Scott, PEN-SIZED DIGITAL 30-SECOND BLOOD GLUCOSE METER The Lancet. ,vol. 1, pp. 778- 779 ,(1987) , 10.1016/S0140-6736(87)92802-9
Shiping Wang, Dongmei Gao, Luxin Yu, Xiuchun Chen, Hongli Che, Yonghua Qin, Mingshe Liu, Preparation and preliminary application of colloidal carbon dipstick for schistosomiasis japonica. Journal of Central South University. Medical sciences. ,vol. 34, pp. 1063- ,(2009)
Tojima T, Nishiki M, Sakairi N, Nishi N, Beta-cyclodextrin-linked chitosan beads: preparation and application to removal of bisphenol A from water. Carbohydrate letters. ,vol. 4, pp. 61- ,(2000)