Accelerated parallel imaging for functional imaging of the human brain

作者: Jacco A. de Zwart , Peter van Gelderen , Xavier Golay , Vasiliki N. Ikonomidou , Jeff H. Duyn

DOI: 10.1002/NBM.1043

关键词: SignalComputer sciencePattern recognitionFunctional imagingTemporal resolutionArtificial intelligenceStability (probability)Human brainNuclear magnetic resonanceHigh fieldReduction (complexity)Parallel imaging

摘要: … fMRI performance, is only partially determined by image SNR. … (whole brain), minimal artifacts, high temporal stability and … Furthermore, many fMRI applications benefit from high field …

参考文章(82)
J.W Carlson, An algorithm for NMR imaging reconstruction based on multiple RF receiver coils Journal of Magnetic Resonance. ,vol. 74, pp. 376- 380 ,(1987) , 10.1016/0022-2364(87)90348-9
Michael A. Ohliger, Aaron K. Grant, Daniel K. Sodickson, Ultimate intrinsic signal-to-noise ratio for parallel MRI: electromagnetic field considerations. Magnetic Resonance in Medicine. ,vol. 50, pp. 1018- 1030 ,(2003) , 10.1002/MRM.10597
Jeff H. Duyn, Charlene X. Tan, Peter van Gelderen, Martin N. Yongbi, High-sensitivity single-shot perfusion-weighted fMRI† Magnetic Resonance in Medicine. ,vol. 46, pp. 88- 94 ,(2001) , 10.1002/MRM.1163
Roland Bammer, Stephen L. Keeling, Michael Augustin, Klaas P. Pruessmann, Roswitha Wolf, Rudolf Stollberger, Hans-Peter Hartung, Franz Fazekas, Improved diffusion-weighted single-shot echo-planar imaging (EPI) in stroke using sensitivity encoding (SENSE). Magnetic Resonance in Medicine. ,vol. 46, pp. 548- 554 ,(2001) , 10.1002/MRM.1226
Adriaan Moelker, Piotr A. Wielopolski, Peter M. T. Pattynama, Relationship between magnetic field strength and magnetic-resonance-related acoustic noise levels MAGMA Magnetic Resonance Materials in Physics, Biology and Medicine. ,vol. 16, pp. 52- 55 ,(2003) , 10.1007/S10334-003-0005-9
Adriaan Moelker, Peter M.T. Pattynama, Acoustic noise concerns in functional magnetic resonance imaging Human Brain Mapping. ,vol. 20, pp. 123- 141 ,(2003) , 10.1002/HBM.10134
R Todd Constable, John C Gore, None, The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI. Magnetic Resonance in Medicine. ,vol. 28, pp. 9- 24 ,(1992) , 10.1002/MRM.1910280103
Jeff Duyn, Specificity of high-resolution BOLD and CBF fMRI at 7 T. Magnetic Resonance in Medicine. ,vol. 51, pp. 644- 645 ,(2004) , 10.1002/MRM.20040
Guoying Liu, Geoffrey Sobering, Alan W. Olson, Peter Van Gelderen, Chrit T. W. Moonen, Fast echo-shifted gradient-recalled MRI : combining a short repetition time with variable T2* weighting Magnetic Resonance in Medicine. ,vol. 30, pp. 68- 75 ,(1993) , 10.1002/MRM.1910300111
N.F. Ramsey, J.S. van den Brink, A.M.C. van Muiswinkel, P.J.M. Folkers, C.T.W. Moonen, J.M. Jansma, R.S. Kahn, Phase navigator correction in 3D fMRI improves detection of brain activation: quantitative assessment with a graded motor activation procedure. NeuroImage. ,vol. 8, pp. 240- 248 ,(1998) , 10.1006/NIMG.1998.0358