Basal perfusion of the cutaneous microcirculation: measurements as a function of anatomic position.

作者: Ethel Tur , Moshe Tur , Howard I. Maibach , Richard H. Guy

DOI: 10.1111/1523-1747.EP12522619

关键词: PlethysmographBlood flowAnatomyMicrocirculationLaser Doppler velocimetryCutaneous microcirculationMedicineBasal (phylogenetics)Blood vesselPerfusion

摘要: Noninvasive optical techniques of photopulse plethysmography (PPG) and laser Doppler velocimetry (LDV) have been used to identify regional variations in the basal skin blood flow humans. The procedures assess either volume or volume-velocity product cutaneous vessel perfusion. Fifty-two anatomic positions studied 10 normal subjects resting horizontally. mean perfusion levels were ranked reveal as a function body site. Groups data collected into cohorts average values for within each cohort compared by Newman-Keuls multiple comparison test. Most transparently, results collection regions (fingers, palms, face, ears) which is much higher than all other positions. More subtle differences some unexpected similarities, however, are also apparent and, cases, agree or, others, conflict, with previously published information. With exceptions, good general agreement between two was observed.

参考文章(15)
Trainor Fs, Crisologo Ja, Shaw Ww, Madden Jl, Kavner D, Lee By, Assessment of the healing potentials of ulcers of the skin by photoplethysmography. Surgery gynecology & obstetrics. ,vol. 148, pp. 233- ,(1979)
Dorothy S. Dittmer, Philip L. Altman, Respiration and Circulation Federation of American Societies for Experimental Biology. ,(1971)
Harry Hayes, A Review of Modern Concepts of Healing of Cutaneous Wounds The Journal of Dermatologic Surgery and Oncology. ,vol. 3, pp. 188- 193 ,(1977) , 10.1111/J.1524-4725.1977.TB00270.X
Dennis Watkins, G. Allen Holloway, An Instrument to Measure Cutaneous Blood Flow Using the Doppler Shift of Laser Light IEEE Transactions on Biomedical Engineering. ,vol. BME-25, pp. 28- 33 ,(1978) , 10.1109/TBME.1978.326374
Ethel Tur, Richard H. Guy, Moshe Tur, Howard I. Maibach, Noninvasive Assessment of Local Nicotinate Pharmacodynamics by Photoplethysmography Journal of Investigative Dermatology. ,vol. 80, pp. 499- 503 ,(1983) , 10.1111/1523-1747.EP12535042
G Allen. Holloway, Dennis W. Watkins, Laser Doppler measurement of cutaneous blood flow. Journal of Investigative Dermatology. ,vol. 69, pp. 306- 309 ,(1977) , 10.1111/1523-1747.EP12507665
H.F. Moustafa, J.W. Hopewell, The evaluation of an isotopic clearance technique for the measurement of skin blood flow in the pig Microvascular Research. ,vol. 11, pp. 147- 153 ,(1976) , 10.1016/0026-2862(76)90046-7
CLAES LUNDBERG, GÖRAN SMEDEGÅRD, Regional differences in skin blood flow as measured by radioactive microspheres. Acta Physiologica Scandinavica. ,vol. 111, pp. 491- 496 ,(1981) , 10.1111/J.1748-1716.1981.TB06768.X
PER SEJRSEN, Blood Flow in Cutaneous Tissue in Man Studied by Washout of Radioactive Xenon Circulation Research. ,vol. 25, pp. 215- 229 ,(1969) , 10.1161/01.RES.25.2.215
Alrick B. Hertzman, Walter C. Randall, Regional differences in the basal and maximal rates of blood flow in the skin. Journal of Applied Physiology. ,vol. 1, pp. 234- 241 ,(1948) , 10.1152/JAPPL.1948.1.3.234