Intraocular Pressure Monitoring Sensors

作者: Kalyan C. Katuri , Sanjay Asrani , Melur K. Ramasubramanian

DOI: 10.1109/JSEN.2007.912539

关键词: Continuous measurementBiomedical engineeringPressure sensorBiomedical equipmentReliability engineeringComputer sciencePressure measurementIntraocular pressureGlaucoma

摘要: … pressure levels. This paper is aimed at providing an up-to-date review of various intraocular pressure … , “Micro coils for an advanced system for measuring intraocular pressure,” in …

参考文章(66)
M. E. Greene, B. G. Gilman, Intraocular Pressure Measurement with Instrumented Contact Lenses Investigative Ophthalmology & Visual Science. ,vol. 13, pp. 299- 302 ,(1974)
R F Brubaker, J S FitzSimon, J W McLaren, Continuous measurement of intraocular pressure in rabbits by telemetry. Investigative Ophthalmology & Visual Science. ,vol. 37, pp. 966- 975 ,(1996)
Chris J. Cakanac, Mark W. Eger, Louis J. Phillips, Melvin E. Lilly, Central corneal thickness and measured IOP: a clinical study. Optometry - Journal of The American Optometric Association. ,vol. 74, pp. 218- 225 ,(2003)
T. Eggers, J. Draeger, K. Hille, C. Marschner, P. Stegmaier, J. Binder, R. Laur, Wireless intra-ocular pressure monitoring system integrated into an artificial lens 1st Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.00EX451). pp. 466- 469 ,(2000) , 10.1109/MMB.2000.893827
Ellis Meng, Choonsup Lee, Yu-Chong Tai, Wolfgang Fink, Mark Humayun, Yoshi Hishinuma, Eui-Hyeok Yang, Thomas George, Optically powered and optically data-transmitting wireless intraocular pressure sensor device ,(2003)
James M. Tielsch, Joanne Katz, Kuldev Singh, Harry A. Quigley, John D. Gottsch, Jonathan Javitt, Alfred Sommer, A Population-based Evaluation of Glaucoma Screening: The Baltimore Eye Survey American Journal of Epidemiology. ,vol. 134, pp. 1102- 1110 ,(1991) , 10.1093/OXFORDJOURNALS.AJE.A116013
E. Meng, Po-Jui Chen, D. Rodger, Yu-Chong Tai, M. Humayun, Implantable parylene MEMS for glaucoma therapy ieee/embs special topic conference on microtechnology in medicine and biology. pp. 116- 119 ,(2005) , 10.1109/MMB.2005.1548399
M. Leonardi, P. Leuenberger, D. Bertrand, A. Bertsch, P. Renaud, A soft contact lens with a MEMS strain gage embedded for intraocular pressure monitoring international conference on solid state sensors actuators and microsystems. ,vol. 2, pp. 1043- 1046 ,(2003) , 10.1109/SENSOR.2003.1216947
ANDREW K. C. LAM, RUFINA CHAN, CHIN-HANG LAM, The validity of a new noncontact tonometer and its comparison with the Goldmann tonometer. Optometry and Vision Science. ,vol. 81, pp. 601- 605 ,(2004) , 10.1097/01.OPX.0000141796.95597.43