Deviations of Lambert-Beer’s law affect corneal refractive parameters after refractive surgery

作者: José R. Jiménez , Francisco Rodríguez-Marín , Rosario G. Anera , Luis Jiménez del Barco

DOI: 10.1364/OE.14.005411

关键词: Beer–Lambert lawOpticsCorneal ablationAblationRefractive surgeryMathematicsReflection (physics)LawLaser rangingCorneaLinear regression

摘要: … Lambert-Beer’s law is assumed for ablation depth but we do not know whether corrections for reflection losses and non-normal incidence are also applied in ablation algorithms (they …

参考文章(11)
Rosario G. Anera, César Villa, José R. Jiménez, Ramón Gutiérrez, Luis Jiménez del Barco, Differences between real and predicted corneal shapes after aspherical corneal ablation. Applied Optics. ,vol. 44, pp. 4528- 4532 ,(2005) , 10.1364/AO.44.004528
José R. Jiménez, Rosario G. Anera, Luis Jiménez del Barco, Enrique Hita, Influence of laser polarization on ocular refractive parameters after refractive surgery Optics Letters. ,vol. 29, pp. 962- 964 ,(2004) , 10.1364/OL.29.000962
José Ramón Jiménez, Rosario González Anera, José Antonio Dı́az, Francisco Pérez-Ocón, Corneal asphericity after refractive surgery when the Munnerlyn formula is applied. Journal of The Optical Society of America A-optics Image Science and Vision. ,vol. 21, pp. 98- 103 ,(2004) , 10.1364/JOSAA.21.000098
Fabrice Manns, Jin-Hui Shen, Per Söderberg, Takaaki Matsui, Jean-Marie Parel, Development of an algorithm for corneal reshaping with a scanning laser beam Applied Optics. ,vol. 34, pp. 4600- 4608 ,(1995) , 10.1364/AO.34.004600
Zsolt Bor, Bela Hopp, Bela Racz, Gabor Szabo, Zsuzsanna Marton, Imola Ratkay, Judit Mohay, Ildiko Sueveges, Agnes Fuest, Physical problems of excimer laser cornea ablation Optical Engineering. ,vol. 32, pp. 2481- 2486 ,(1993) , 10.1117/12.145357
George H. Pettit, Excimer laser ablation of the cornea Optical Engineering. ,vol. 34, pp. 661- 667 ,(1995) , 10.1117/12.190408
Alfred Vogel, Vasan Venugopalan, Mechanisms of pulsed laser ablation of biological tissues. Chemical Reviews. ,vol. 103, pp. 577- 644 ,(2003) , 10.1021/CR010379N
Jos� Ram�n Jim�nez, Rosario Gonz�lez Anera, Luis Jim�nez del Barco, Enrique Hita, Francisco P�rez-Oc�n, Correction factor for ablation algorithms used in corneal refractive surgery with gaussian-profile beams. Optics Express. ,vol. 13, pp. 336- 343 ,(2005) , 10.1364/OPEX.13.000336
David Huang, Muhammad Arif, None, Spot size and quality of scanning laser correction of higher-order wavefront aberrations. Journal of Cataract and Refractive Surgery. ,vol. 28, pp. 407- 416 ,(2002) , 10.1016/S0886-3350(01)01163-4