The Performance of Ultra-Low-Volume Flush Toilets in Phoenix

作者: Damann L. Anderson , Robert L. Siegrist

DOI: 10.1002/J.1551-8833.1989.TB03181.X

关键词: ToiletUltra-low volumeField conditionsEnvironmental engineeringWastewaterFlow reductionWater consumptionEnvironmental sciencePhoenixDrainage

摘要: The performance of ultra-low-volume (ULV) toilet fixtures was studied under field conditions in Phoenix, Ariz. Two residential subdivisions were compared, one utilizing conventional (>3.5 gal/flush) and using ULV (0.8 gal/flush). study evaluated the water savings wastewater flow reduction provided by fixtures, their effect on drainage sewer transport, in-house acceptance users compared with counterparts.

参考文章(2)
C. A. Cole, W. E. Sharpe, D. D. Fritton, Restoration of failing on-site wastewater disposal systems using water conservation Journal of Water Pollution Control Federation. ,vol. 56, pp. 858- 866 ,(1984)
Robert L. Siegrist, Minimum-flow plumbing fixtures Journal - American Water Works Association. ,vol. 75, pp. 342- 347 ,(1983) , 10.1002/J.1551-8833.1983.TB05157.X