Online detection of inter-turn short circuit faults in dry-type air-core reactor

作者: Yanzhen Zhao , Xikui Ma , Jichao Yang

DOI: 10.3233/JAE-2012-1494

关键词: Field (physics)Turn (geometry)Electrical engineeringMagnetic fieldShort circuitFault (power engineering)Type (model theory)EngineeringVoltageExcitation

摘要: Inter-turn short circuit faults are among the common occurring in dry-type air-core reactor. This paper presents an online detection method of inter-turn for reactors by using search coils. Since this type fault creates shorted turns which there high induced currents that can produce intense reversed magnetic field, field distribution is no longer symmetrical. The variety from normal condition to be monitored Based on coupled method, reactor and induction voltage coils computed different conditions. proper mounted positions suggested. proposed has been verified effective easy implementation experimentation.

参考文章(3)
Zhang Yi, Turn-to-Turn Faults Protection of EHV Shunt Reactors Journal of Tianjin University. ,(2005)
Liu Hua, Liu Jianjun, Wang Yongyong, Wen Xianglong, Burn-out of dry hollow parallel reactors Heilongjiang Electric Power. ,(2003)