Photochemical-chemiluminometric determination of aldicarb in a fully automated multicommutation based flow-assembly

作者: M Palomeque , J.A Garcı́a Bautista , M Catalá Icardo , J.V Garcı́a Mateo , J Martı́nez Calatayud

DOI: 10.1016/J.ACA.2004.02.031

关键词: Mercury-vapor lampAnalytical chemistryAldicarbChemistryFully automatedChemiluminescencePhotodegradationDetection limitPotassium permanganateTransient signalChromatography

摘要: Abstract A sensitive and fully automated method for determination of aldicarb in technical formulations (Temik) mineral waters is proposed. The automation the flow-assembly based on multicommutation approach, which uses a set solenoid valves acting as independent switchers. operating cycle obtaining typical analytical transient signal can be easily programmed by means home-made software running Windows environment. manifold provided with photoreactor consisting 150 cm long × 0.8 mm i.d. piece PTFE tubing coiled around 20 W low-pressure mercury lamp. performed basis iron(III) catalytic mineralization pesticide UV irradiation (150 s), chemiluminescent (CL) behavior photodegradated presence potassium permanganate quinine sulphate sensitizer. turns very week into strongly photoproduct. linear over range 2.2–100.0 μg l −1 aldicarb; limit detection 0.069 μg l ; reproducibility (as R.S.D. 20 peaks 24 μg l solution) 3.7% sample throughput 17 h .

参考文章(39)
L. Campanella, S. De Luca, M.P. Sammartino, M. Tomassetti, A new organic phase enzyme electrode for the analysis of organophosphorus pesticides and carbamates Analytica Chimica Acta. ,vol. 385, pp. 59- 71 ,(1999) , 10.1016/S0003-2670(98)00806-X
Y Picó, G Font, JC Moltó, J Manes, None, Pesticide residue determination in fruit and vegetables by liquid chromatography-mass spectrometry. Journal of Chromatography A. ,vol. 882, pp. 153- 173 ,(2000) , 10.1016/S0021-9673(00)00294-6
Carl J. Miles, H. Anson. Moye, Postcolumn photolysis of pesticides for fluorometric determination by high-performance liquid chromatography Analytical Chemistry. ,vol. 60, pp. 220- 226 ,(1988) , 10.1021/AC00154A007
Xiaodong Ma, Chongjiu Li, Chuanjiang Tao, Wei Liu, Shanshan Zheng, None, Multi-residue determination of 41 insecticides in garlic by gas chromatography and ion trap mass spectrometry using the selective ion storage technique. Rapid Communications in Mass Spectrometry. ,vol. 15, pp. 15- 19 ,(2001) , 10.1002/1097-0231(20010115)15:1<15::AID-RCM186>3.0.CO;2-6
Juan Carlos Moltó, José Miguel Soriano, Beatriz Jiménez, Guillermina Font, Analysis of Carbamate Pesticides and Their Metabolites in Water by Solid Phase Extraction and Liquid Chromatography: A Review Critical Reviews in Analytical Chemistry. ,vol. 31, pp. 19- 52 ,(2001) , 10.1080/20014091076677
S. Rodolico, R. Giovinazzo, M. Mosconi, Comparison between ELISAs and traditional analytical methods to determine pesticide pollution in water. Bulletin of Environmental Contamination and Toxicology. ,vol. 58, pp. 644- 650 ,(1997) , 10.1007/S001289900382