Seismic response mitigation of chemical plant components by passive control techniques

作者: F. Paolacci , R. Giannini , M. De Angelis

DOI: 10.1016/J.JLP.2013.03.003

关键词: Passive controlEngineeringTuned mass damperChemical plantStructural engineeringProcess (computing)Frame (networking)DamperFractionating columnStorage tankControl and Systems EngineeringManagement Science and Operations ResearchFood scienceIndustrial and Manufacturing EngineeringEnergy Engineering and Power TechnologyGeneral Chemical EngineeringSafety, Risk, Reliability and Quality

摘要: This paper deals with the applicability of seismic passive control in major-hazard chemical installations. The objective is to show numerically and experimentally Passive Control Techniques (PCT) industrial plants. Consequently, main components a process plant are classified collected into limited number classes; for each class, damages caused by past earthquakes described most vulnerable identified. A synthesis effects on different typologies also presented suitable innovative protection systems, particular techniques (PCT), acknowledged. Finally, effectiveness PCT reducing response proved three representative case studies: base isolated above-ground storage tank, distillation column connected elastoplastic dampers adjacent service frame an application non-conventional Tuned Mass Dampers support frame.

参考文章(55)
Maurizio De Angelis, Salvatore Perno, Anna Reggio, Dynamic response and optimal design of structures with large mass ratio TMD Earthquake Engineering & Structural Dynamics. ,vol. 41, pp. 41- 60 ,(2012) , 10.1002/EQE.1117
M. Basili, M. De Angelis, G. Fraraccio, Shaking table experimentation on adjacent structures controlled by passive and semi-active MR dampers Journal of Sound and Vibration. ,vol. 332, pp. 3113- 3133 ,(2013) , 10.1016/J.JSV.2012.12.040
A.V. Bergami, C. Nuti, A design procedure of dissipative braces for seismic upgrading structures Earthquakes and Structures. ,vol. 4, pp. 85- 108 ,(2013) , 10.12989/EAS.2013.4.1.085
E. Salzano, I. Iervolino, G. Fabbrocino, Seismic risk of atmospheric storage tanks in the framework of quantitative risk analysis Journal of Loss Prevention in The Process Industries. ,vol. 16, pp. 403- 409 ,(2003) , 10.1016/S0950-4230(03)00052-4
B. F. Spencer, S. Nagarajaiah, State of the Art of Structural Control Journal of Structural Engineering. ,vol. 129, pp. 845- 856 ,(2003) , 10.1061/(ASCE)0733-9445(2003)129:7(845)
Matthias Wieschollek, Benno Hoffmeister, Markus Feldmann, Experimental and Numerical Investigations on Nozzle Reinforcements Volume 8: Seismic Engineering. ,(2013) , 10.1115/PVP2013-97430
Tetsuya Matsui, Sloshing in a Cylindrical Liquid Storage Tank With a Single-Deck Type Floating Roof Under Seismic Excitation Journal of Pressure Vessel Technology-transactions of The Asme. ,vol. 131, pp. 021303- ,(2009) , 10.1115/1.3062939
M. Basili, M. De Angelis, A reduced order model for optimal design of 2-mdof adjacent structures connected by hysteretic dampers Journal of Sound and Vibration. ,vol. 306, pp. 297- 317 ,(2007) , 10.1016/J.JSV.2007.05.012
Michel S. Chalhoub, James M. Kelly, Shake Table Test of Cylindrical Water Tanks in Base-Isolated Structures Journal of Engineering Mechanics-asce. ,vol. 116, pp. 1451- 1472 ,(1990) , 10.1061/(ASCE)0733-9399(1990)116:7(1451)