A three-part system for refining intraocular lens power calculations

作者: Jack T. Holladay , Kathryn H. Musgrove , Thomas C. Prager , John W. Lewis , Thomas Y. Chandler

DOI: 10.1016/S0886-3350(88)80059-2

关键词: KeratometerAxial lengthRefractionIntraocular lens power calculationIntraocular lens powerPower calculationsIntraocular lensPower (physics)OpticsMedicine

摘要: A three-part system that determines the correct power for an intraocular lens (IOL) to achieve a desired postoperative refraction is presented. The three components are (1) data screening criteria identify improbable axial length and keratometry measurements, (2) new IOL calculation formula exceeds current accuracy of other formulas short, medium, long eyes, (3) personalized "surgeon factor" adjusts any consistent bias in surgeon's results, from source, based on reverse solution formula; uses stabilized refraction, dioptric implanted IOL, preoperative corneal measurements calculate surgeon factor. improved was proven by performing calculations 2,000 eyes 12 surgeons comparing results seven currently used formulas.

参考文章(30)
M A Galin, A Linksz, S N Fyodorov, Calculation of the optical power of intraocular lenses Investigative Ophthalmology & Visual Science. ,vol. 14, pp. 625- 628 ,(1975)
Richard D Binkhorst, The accuracy of ultrasonic measurement of the axial length of the eye. Ophthalmic Surgery and Lasers. ,vol. 12, pp. 363- 365 ,(1981) , 10.3928/1542-8877-19810501-16
John Retzlaff, Posterior chamber implant power calculation: regression formulas American Intra-Ocular Implant Society Journal. ,vol. 6, pp. 268- 270 ,(1980) , 10.1016/S0146-2776(80)80076-0
John Retzlaff, A new intraocular lens calculation formula American Intra-Ocular Implant Society Journal. ,vol. 6, pp. 148- 152 ,(1980) , 10.1016/S0146-2776(80)80008-5
Donald R. Sanders, Manus C. Kraff, Improvement of intraocular lens power calculation using empirical data American Intra-Ocular Implant Society Journal. ,vol. 6, pp. 263- 267 ,(1980) , 10.1016/S0146-2776(80)80075-9
K. J. Hoffer, Accuracy of ultrasound intraocular lens calculation. Archives of Ophthalmology. ,vol. 99, pp. 1819- 1823 ,(1981) , 10.1001/ARCHOPHT.1981.03930020693014
Kenneth J. Hoffer, Biometry of 7,500 Cataractous Eyes American Journal of Ophthalmology. ,vol. 90, pp. 360- 368 ,(1980) , 10.1016/S0002-9394(14)74917-7
M C Colenbrander, Calculation of the power of an iris clip lens for distant vision. British Journal of Ophthalmology. ,vol. 57, pp. 735- 740 ,(1973) , 10.1136/BJO.57.10.735
KARL C. OSSOINIG, Standardized echography: basic principles, clinical applications, and results. International Ophthalmology Clinics. ,vol. 19, pp. 127- 210 ,(1979) , 10.1097/00004397-197901940-00007