Short communication: spinal bone density measured with a 5 s scan.

作者: F M A Buxton , G M Blake , J C Parker , M K Lewis , I Fogelman

DOI: 10.1259/0007-1285-66-783-275

关键词: 5SBone mineralDual-Photon AbsorptiometryBone densityLow dose ctMaterials scienceBone massNuclear medicine

摘要: Absorptiometry provides a convenient, non-invasive method of measuring bone mass in the skeleton with high precision and low radiation dose to patient (Tothill, 1989). Dual photon absorptiometry (DPA) based on radionuclide source 153Gd was developed for mineral density (BMD) at clinically important sites spine hip (Wilson & Madsen, 1977). Recently, dual X-ray (DXA) has superseded DPA (Cullum et al, Compared DPA, DXA advantages improved (coefficient variation 1% spinal compared 2–3% DPA) shorter scanning times (6–8 min 20–30 (Sorenson Use an tube instead eliminates problems associated radioactive decay (Lindsay 1987). In most recent development technology least two manufacturers have introduced scanners fan beam configuration coupled multidetector head ...

参考文章(9)
Donald F. Morrison, Multivariate statistical methods Published in <b>1976</b> in New York NY) by McGraw-Hill. ,(1976)
P Tothill, Methods of bone mineral measurement. Physics in Medicine and Biology. ,vol. 34, pp. 543- 572 ,(1989) , 10.1088/0031-9155/34/5/001
I. D. Cullum, P. J. Ell, J. P. Ryder, X-ray dual-photon absorptiometry: a new method for the measurement of bone density. British Journal of Radiology. ,vol. 62, pp. 587- 592 ,(1989) , 10.1259/0007-1285-62-739-587
CHARLES R. WILSON, MARK MADSEN, Dichromatic Absorptiometry of Vertebral Bone Mineral Content Investigative Radiology. ,vol. 12, pp. 180- 184 ,(1977) , 10.1097/00004424-197703000-00014
James A. Sorenson, Peter R. Duke, Steven W. Smith, Simulation studies of dual-energy x-ray absorptiometry Medical Physics. ,vol. 16, pp. 75- 80 ,(1989) , 10.1118/1.596405
R. Lindsay, C. Fey, A. Haboubi, Dual photon absorptiometric measurements of bone mineral density increase with source life. Calcified Tissue International. ,vol. 41, pp. 293- 294 ,(1987) , 10.1007/BF02555232
M. K. Lewis, G. M. Blake, I. Fogelman, 59. Patient dosimetry studies on the hologic QDR-1000 and QDR-1000/W Nuclear Medicine Communications. ,vol. 13, pp. 224- ,(1992) , 10.1097/00006231-199204000-00061
P. J. RYAN, G. M. BLAKE, I. FOGELMAN, POSTMENOPAUSAL SCREENING FOR OSTEOPENIA Rheumatology. ,vol. 31, pp. 823- 828 ,(1992) , 10.1093/RHEUMATOLOGY/31.12.823
G. M. Blake, C. M. Tong, I. Fogelman, Intersite comparison of the Hologic QDR-1000 dual energy X-ray bone densitometer. British Journal of Radiology. ,vol. 64, pp. 440- 446 ,(1991) , 10.1259/0007-1285-64-761-440