Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with V-ribs with symmetrical gaps

作者: Rajesh Maithani , J.S. Saini

DOI: 10.1016/J.EXPTHERMFLUSCI.2015.09.010

关键词: Angle of attackHeat transferDuct (flow)Surface finishReynolds numberHeat transfer coefficientMechanicsOpticsNusselt numberMaterials scienceTurbulence

摘要: Abstract An experimental study has been carried out for enhancement of heat transfer coefficient a solar air heater having roughened duct artificially in the form V-ribs with symmetrical gaps as turbulence promoter. In present work an investigation and friction artificial roughness were investigated. The encompassed Reynolds number (Re) ranging from 4000 to 18,000, Number (Ng) values 1–5, relative gap width (g/e) pitch (P/e) 6–12, angle attack (α) range 30–75° height (e/D) 0.043. For Nusselt (Nu), maximum order 3.6 times that smooth obtained, similarly factor (f) also increases by 3.67 folds duct. rib parameters corresponding increase Nu f Ng = 3, g/e = 4, P/e = 10 α = 60°. Based on data, correlations have developed function flow number.

参考文章(22)
L.M. Wright, J.C. Fu, W.L., Han, Thermal Performance of Angled, V-Shaped, and W-Shaped Rib Turbulators in Rotating Rectangular Cooling Channels (AR=4:1) Journal of Turbomachinery-transactions of The Asme. ,vol. 126, pp. 604- 614 ,(2004) , 10.1115/1.1791286
X. Gao, B. Sundén, Heat transfer distribution in rectangular ducts with V-shaped ribs Heat and Mass Transfer. ,vol. 37, pp. 315- 320 ,(2001) , 10.1007/S002310000148
J. C. Han, Y. M. Zhang, C. P. Lee, Augmented Heat Transfer in Square Channels With Parallel, Crossed, and V-Shaped Angled Ribs Journal of Heat Transfer-transactions of The Asme. ,vol. 113, pp. 590- 596 ,(1991) , 10.1115/1.2910606
R. Jia, B. Sunde´n, M. Faghri, Computational Analysis of Heat Transfer Enhancement in Square Ducts With V-Shaped Ribs: Turbine Blade Cooling Journal of Heat Transfer-transactions of The Asme. ,vol. 127, pp. 425- 433 ,(2005) , 10.1115/1.1865220
Xiufang Gao, Bengt Sundén, PIV measurement of the flow field in rectangular ducts with 60° parallel, crossed and V-shaped ribs Experimental Thermal and Fluid Science. ,vol. 28, pp. 639- 653 ,(2004) , 10.1016/J.EXPTHERMFLUSCI.2003.10.005
S.C. Lau, R.T. Kukreja, R.D. Mcmillin, Effects of V-shaped rib arrays on turbulent heat transfer and friction of fully developed flow in a square channel International Journal of Heat and Mass Transfer. ,vol. 34, pp. 1605- 1616 ,(1991) , 10.1016/0017-9310(91)90140-A
Rongguang Jia, Arash Saidi, and, Bengt Sunden, Heat Transfer Enhancement in Square Ducts With V-Shaped Ribs Journal of Turbomachinery-transactions of The Asme. ,vol. 125, pp. 788- 791 ,(2003) , 10.1115/1.1622708