Surface plasmon resonance analysis of staphylococcal enterotoxin B in food.

作者: AVRAHAM RASOOLY

DOI: 10.4315/0362-028X-64.1.37

关键词: BiosensorSpr biosensorMatrix (chemical analysis)AntigenChemistryAntibodyMicrobiologySurface plasmon resonanceEnterotoxinChromatography

摘要: Surface plasmon resonance (SPR) biosensors are electro-optical instruments used for analyzing real-time protein-protein interactions. This work evaluates an SPR biosensor (Biacore 3000) in the detection of staphylococcal enterotoxin B (SEB) foods. A sandwich immunosensor involving two antibodies was used. The capturing antibody, bound covalently to surface chip, performs initial binding antigen and a second antibody binds captured antigen. makes verification possible amplifies signal. Pure SEB as well spiked foods (milk meat) were detected with little interference from food matrix. In control experiments uncontaminated samples no significant signal detected. assay detects at ~10 ng/ml rapidly, within 2 min. entire measurement cycle (including washing chip regeneration) may take 5 min using one or 8 antibodies. These ...

参考文章(34)
L Rasooly, N R Rose, D B Shah, A Rasooly, In vitro assay of Staphylococcus aureus enterotoxin A activity in food. Applied and Environmental Microbiology. ,vol. 63, pp. 2361- 2365 ,(1997) , 10.1128/AEM.63.6.2361-2365.1997
Richard G Woodbury, Cecilia Wendin, James Clendenning, Jose Melendez, Jerry Elkind, Dwight Bartholomew, Stanley Brown, Clement E Furlong, Construction of biosensors using a gold-binding polypeptide and a miniature integrated surface plasmon resonance sensor Biosensors and Bioelectronics. ,vol. 13, pp. 1117- 1126 ,(1998) , 10.1016/S0956-5663(98)00060-8
John D. Olson, Peter R. Panfili, Richard Armenta, Mary Beth Femmel, Holly Merrick, Jenny Gumperz, Marion Goltz, Robert F. Zuk, A silicon sensor-based filtration immunoassay using biotin-mediated capture. Journal of Immunological Methods. ,vol. 134, pp. 71- 79 ,(1990) , 10.1016/0022-1759(90)90113-A
Matthew Fivash, Eric M Towler, Robert J Fisher, BIACORE FOR MACROMOLECULAR INTERACTION Current Opinion in Biotechnology. ,vol. 9, pp. 97- 101 ,(1998) , 10.1016/S0958-1669(98)80091-8
Robert A. Ogert, J. Edward Brown, Bal Ram Singh, Lisa C. Shriver-Lake, Frances S. Ligler, Detection of Clostridium botulinum toxin A using a fiber optic-based biosensor. Analytical Biochemistry. ,vol. 205, pp. 306- 312 ,(1992) , 10.1016/0003-2697(92)90440-I
Lars G. Fägerstam, Åsa Frostell, Robert Karlsson, Mari Kullman, Anita Larsson, Magnus Malmqvist, Helena Butt, Detection of antigen-antibody interactions by surface plasmon resonance. Application to epitope mapping. Journal of Molecular Recognition. ,vol. 3, pp. 208- 214 ,(1990) , 10.1002/JMR.300030507
Keeley D. King, George P. Anderson, Karen E. Bullock, Meredith J. Regina, Elric W. Saaski, Frances S. Ligler, Detecting staphylococcal enterotoxin B using an automated fiber optic biosensor. Biosensors and Bioelectronics. ,vol. 14, pp. 163- 170 ,(1999) , 10.1016/S0956-5663(98)00108-0
L Ghindilis, Andrey, Plamen Atanasov, Michael Wilkins, Ebtisam Wilkins, Immunosensors: electrochemical sensing and other engineering approaches Biosensors and Bioelectronics. ,vol. 13, pp. 113- 131 ,(1998) , 10.1016/S0956-5663(97)00031-6
Chris A. Rowe, Stephanie B. Scruggs, Mark J. Feldstein, Joel P. Golden, Frances S. Ligler, An Array Immunosensor for Simultaneous Detection of Clinical Analytes Analytical Chemistry. ,vol. 71, pp. 433- 439 ,(1999) , 10.1021/AC980798T
M. Betley, J. Mekalanos, Staphylococcal enterotoxin A is encoded by phage Science. ,vol. 229, pp. 185- 187 ,(1985) , 10.1126/SCIENCE.3160112