Bone Density Data Among Technologies and Manufacturers

作者: Sydney Lou Bonnick

DOI: 10.1007/978-1-60327-499-9_6

关键词: RadiologyProximal femurFemoral neckMetabolic bone diseaseBone densityMedicine

摘要: The extraordinary advances in bone density technology over the last 40 years have enhanced physician’s ability to detect and manage metabolic disease. At same time, these created a dilemma as physicians attempted compare results obtained on early dual-photon (DPA) devices with today’s dual-energy X-ray (DXA) devices. As DXA has advanced, data from pencil-beam systems are being compared fan-array systems. Compounding this issue is that one manufacturer’s device may need be another device, which been calibrated very differently. This situation not dissimilar circumstances during evolution of other types quantitative measurement techniques used clinical medicine. For example, some parameter blood initially performed using type assay, only later replaced by different assay. There ranges normal, depending upon assay even laboratory.

参考文章(31)
H S Barden, R B Mazess, Measurement of bone by dual-photon absorptiometry (DPA) and dual-energy X-ray absorptiometry (DEXA). Annales Chirurgiae Et Gynaecologiae. ,vol. 77, pp. 197- 203 ,(1988)
P. Eiken, O. Bärenholdt, L.Bjørn Jensen, J. Gram, S.Pors Nielsen, Switching from DXA pencil-beam to fan-beam. I: Studies in vitro at four centers. Bone. ,vol. 15, pp. 667- 670 ,(1994) , 10.1016/8756-3282(94)90315-8
Y. Lu, T. Fuerst, S. Hui, H. K. Genant, Standardization of bone mineral density at femoral neck, trochanter and Ward's triangle. Osteoporosis International. ,vol. 12, pp. 438- 444 ,(2001) , 10.1007/S001980170087
G M Blake, J C Parker, F M A Buxton, I Fogelman, Dual X-ray absorptiometry: a comparison between fan beam and pencil beam scans British Journal of Radiology. ,vol. 66, pp. 902- 906 ,(1993) , 10.1259/0007-1285-66-790-902
A. C. Looker, H. W. Wahner, W. L. Dunn, M. S. Calvo, T. B. Harris, S. P. Heyse, C. C. Johnston, R. L. Lindsay, Proximal femur bone mineral levels of US adults Osteoporosis International. ,vol. 5, pp. 389- 409 ,(1995) , 10.1007/BF01622262
Eric S. Orwoll, Shelia K. Oviatt, Longitudinal precision of dual-energy X-ray absorptiometry in a multicenter study Journal of Bone and Mineral Research. ,vol. 6, pp. 191- 197 ,(2009) , 10.1002/JBMR.5650060213
A. C. Looker, H. W. Wahner, W. L. Dunn, M. S. Calvo, T. B. Harris, S. P. Heyse, C. C. Johnston Jr, R. Lindsay, Updated Data on Proximal Femur Bone Mineral Levels of US Adults Osteoporosis International. ,vol. 8, pp. 468- 490 ,(1998) , 10.1007/S001980050093
John A. Shepherd, Xiao Guang Cheng, Ying Lu, Chris Njeh, Jorg Toschke, Klaus Engelke, Michael Grigorian, Harry K. Genant, Universal Standardization of Forearm Bone Densitometry Journal of Bone and Mineral Research. ,vol. 17, pp. 734- 745 ,(2002) , 10.1359/JBMR.2002.17.4.734
Sanford Baim, Mary B. Leonard, Maria-Luisa Bianchi, Didier B. Hans, Heidi J. Kalkwarf, Craig B. Langman, Frank Rauch, Official Positions of the International Society for Clinical Densitometry and Executive Summary of the 2007 ISCD Pediatric Position Development Conference Journal of Clinical Densitometry. ,vol. 11, pp. 6- 21 ,(2006) , 10.1016/J.JOCD.2007.12.002
T. L. KELLY, D. M. SLOVIK, D. A. SCHOENFELD, R. M. NEER, Quantitative digital radiography versus dual photon absorptiometry of the lumbar spine. The Journal of Clinical Endocrinology and Metabolism. ,vol. 67, pp. 839- 844 ,(1988) , 10.1210/JCEM-67-4-839