摘要: Abstract A triggered spark-gap switch together with a LCR trigger circuit has been developed in order to produce high levels of pulsed corona plasma at high-repetition rate and long lifetime. The is flushed air gas flow up 100 m 3 /h. Experiments are carried out 10 kW average output power, 12 J/pulse, 900 pps (pulses per second).