The Membrane Sensors Sensitive to Fluoxetine - Optimization of the Analytical Parameters

作者: Joanna Drozd ,

DOI: 10.6000/1927-5129.2015.11.56

关键词: EtherFluoxetine HydrochlorideIon selective electrodeNuclear chemistryAdipatePotentiometric titrationTetraphenylborateSolventChemistryMembraneChromatography

摘要: Background : The analytical characteristics of electrodes containing liquid PVC membrane depend on the purity electroactive material and applied solvents. Methods Fluoxetine - one H-bond donor, formed ion-associated complexes with tetraphenylborate, tetrakis(4-chlorophenyl)borate dipicrylamine. To confirm quality obtained elemental TLC analysis were performed. construction general fluoxetine ion-selective plastic sensors, based use a – ion-pair complex as 2-nitrophenyloctyl ether, bis(2-ethylhexyl)sebacate, bis(2-butylpentyl)adipate 1-isopropyl-4-nitrobenzene solvent mediators. Results electrode Fl-ClTPB-NPhOE (fluoxetine-tetrakis(4-chlorophenyl)borate-2-nitrophenyloctyl ether showed linear response to at concentration ranges 30.93 2.16 g·L -1 super Nernstian cationic slope 60.19 mV·decade . Conclusions This sensor was used for potentiometric determination content hydrochloride in pure form pharmaceutical formula.

参考文章(17)
E. Siska, E. Pungor, Potentiometric determination of tetraphenylborate ions with silver nitrate. Determination of silver, potassium and thallium(I) Fresenius Journal of Analytical Chemistry. ,vol. 257, pp. 12- 18 ,(1971) , 10.1007/BF00424177
Rudolf Eugster, Thomas Rosatzin, Bruno Rusterholz, Barbara Aebersold, Urs Pedrazza, Denise Rüegg, Angela Schmid, Ursula E. Spichiger, Wilhelm Simon, Plasticizers for liquid polymeric membranes of ion-selective chemical sensors Analytica Chimica Acta. ,vol. 289, pp. 1- 13 ,(1994) , 10.1016/0003-2670(94)80001-4
H. Ibrahim, Y.M. Issa, Hazem M. Abu-Shawish, Potentiometric flow injection analysis of dicyclomine hydrochloride in serum, urine and milk Analytica Chimica Acta. ,vol. 532, pp. 79- 88 ,(2005) , 10.1016/J.ACA.2004.10.046
M. Goreti F. Sales, José F.C. Tomás, Sandra R. Lavandeira, Flow injection potentiometric determination of chlorpromazine Journal of Pharmaceutical and Biomedical Analysis. ,vol. 41, pp. 1280- 1286 ,(2006) , 10.1016/J.JPBA.2006.03.027
Genowefa Misztal, Robert Skibiński, Chromatographic analysis of new antidepressant drugs by normal- and reversed-phase TLC Jpc-journal of Planar Chromatography-modern Tlc. ,vol. 14, pp. 300- 304 ,(2001) , 10.1556/JPC.14.2001.4.14
T. Kimbeni Malongo, B. Blankert, O. Kambu, K. Amighi, J. Nsangu, J.-M. Kauffmann, Amodiaquine polymeric membrane electrode. Journal of Pharmaceutical and Biomedical Analysis. ,vol. 41, pp. 70- 76 ,(2006) , 10.1016/J.JPBA.2005.10.014
E.M. Hussien, F.M. Abdel-Gawad, Y.M. Issa, Ion-selective electrodes for determination of fluoxetine in capsules and in biological fluids Biochemical Engineering Journal. ,vol. 53, pp. 210- 215 ,(2011) , 10.1016/J.BEJ.2010.10.015
A. Craggs, G. J. Moody, J. D. R. Thomas, PVC matrix membrane ion-selective electrodes. Construction and laboratory experiments Journal of Chemical Education. ,vol. 51, pp. 541- ,(1974) , 10.1021/ED051P541
Bashaer A. Al-Phalahy, Nabil S. Nassory, Shahbaz A. Maki, Preparation and Potentiometric Study of Promethazine Hydrochloride Selective Electrodes and Their Use in Determining Some Drugs Turkish Journal of Chemistry. ,vol. 32, pp. 539- 548 ,(2008)