Rapid detection and quantitation of ketamine and norketamine in urine and oral fluid by wooden-tip electrospray ionization mass spectrometry

作者: Pui-Kin So , Tsz-Tsun Ng , Haixing Wang , Bin Hu , Zhong-Ping Yao

DOI: 10.1039/C3AN36641C

关键词: NorketamineSample preparationElectrospray ionizationLinear rangeChemistryMass spectrometryUrineKetamineMetaboliteChromatography

摘要: … This study demonstrated that WT-ESI-MS could be applied as a rapid method for detection and quantitation of ketamine and norketamine in biological fluids. This method involves only …

参考文章(33)
Bin Hu, Pui-Kin So, Huanwen Chen, Zhong-Ping Yao, Electrospray Ionization Using Wooden Tips Analytical Chemistry. ,vol. 83, pp. 8201- 8207 ,(2011) , 10.1021/AC2017713
Tiina J. Kauppila, Risto Kostiainen, Niina M. Suni, Pia Lindfors, Olli Laine, Pekka Östman, Ilkka Ojanperä, Tapio Kotiaho, Matrix effect in the analysis of drugs of abuse from urine with desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS) and desorption electrospray ionization-mass spectrometry (DESI-MS) Analytica Chimica Acta. ,vol. 699, pp. 73- 80 ,(2011) , 10.1016/J.ACA.2011.05.004
Nicholas Edward Manicke, Paul Abu-Rabie, Neil Spooner, Zheng Ouyang, R Graham Cooks, None, Quantitative analysis of therapeutic drugs in dried blood spot samples by paper spray mass spectrometry: an avenue to therapeutic drug monitoring. Journal of the American Society for Mass Spectrometry. ,vol. 22, pp. 1501- 1507 ,(2011) , 10.1007/S13361-011-0177-X
Pai-Sheng Cheng, Chien-Yu Fu, Choung-Huei Lee, Chiareiy Liu, Chun-Sheng Chien, GC–MS quantification of ketamine, norketamine, and dehydronorketamine in urine specimens and comparative study using ELISA as the preliminary test methodology Journal of Chromatography B. ,vol. 852, pp. 443- 449 ,(2007) , 10.1016/J.JCHROMB.2007.02.005
V. Vindenes, H.M.E. Lund, W. Andresen, H. Gjerde, S.E. Ikdahl, A.S. Christophersen, E.L. Øiestad, Detection of drugs of abuse in simultaneously collected oral fluid, urine and blood from Norwegian drug drivers Forensic Science International. ,vol. 219, pp. 165- 171 ,(2012) , 10.1016/J.FORSCIINT.2012.01.001
Sherri L. Kacinko, Allan J. Barnes, Insook Kim, Eric T. Moolchan, Lisa Wilson, Gail A. Cooper, Claire Reid, Dene Baldwin, Chris W. Hand, Marilyn A. Huestis, Performance characteristics of the Cozart RapiScan Oral Fluid Drug Testing System for opiates in comparison to ELISA and GC/MS following controlled codeine administration. Forensic Science International. ,vol. 141, pp. 41- 48 ,(2004) , 10.1016/J.FORSCIINT.2003.12.003
Rune Isak Dupont Birkler, Rasmus Telving, Ole Ingemann-Hansen, Annie Vesterby Charles, Mogens Johannsen, Mette Findal Andreasen, Screening analysis for medicinal drugs and drugs of abuse in whole blood using ultra-performance liquid chromatography time-of-flight mass spectrometry (UPLC–TOF-MS)—Toxicological findings in cases of alleged sexual assault Forensic Science International. ,vol. 222, pp. 154- 161 ,(2012) , 10.1016/J.FORSCIINT.2012.05.019