Dosimetric verification of a commercial collapsed cone algorithm in simulated clinical situations.

作者: Andrew Nisbet , Ian Beange , Hans-Stephan Vollmar , Catherine Irvine , Andrew Morgan

DOI: 10.1016/J.RADONC.2004.06.007

关键词: Radiation treatment planningThermoluminescent dosimeterThermoluminescence dosimeterImaging phantomPhoton beamsCollapsed coneAlgorithmComputer scienceHomogeneousPencil beam algorithm

摘要: Abstract Background and purpose This work reports a detailed study carried out in two UK radiotherapy centres of the dosimetric accuracy collapsed cone algorithm commercial treatment planning system (Helax-TMS) simulated clinical situations. Materials methods Initially homogeneous media is evaluated for an extensive set simple complex fields. Water, lung bone substitute epoxy resin material were then used to assess inhomogeneous compare its with pencil beam currently use. Finally semi-anatomic phantom anthropomorphic employed using ups. Thermoluminescence dosimeter (TLD) measurements made ionisation chambers otherwise. Nominal 4, 6 15 MV photon beams studied. Results For most cases agreement between measured calculated dose within ±2% or ±2 mm. In heterogeneities situations it observed that also generally Specific instances where difference values exceed this are highlighted. Conclusions It can be concluded present should considered preference algorithms normally but there may still some discrepancy calculations measurement.

参考文章(39)
Anders Ahnesjö, Mikael Saxner, Ingvar Thorslund, Modelling of photon beam spectral variations Springer, Berlin, Heidelberg. pp. 227- 228 ,(2000) , 10.1007/978-3-642-59758-9_85
B. H. Shahine, M. S. A. L. Al-Ghazi, E. El-Khatib, Experimental evaluation of interface doses in the presence of air cavities compared with treatment planning algorithms Medical Physics. ,vol. 26, pp. 350- 355 ,(1999) , 10.1118/1.598526
Coen Hurkmans, Tommy Knöös, Per Nilsson, Gudrun Svahn-Tapper, Hans Danielsson, Limitations of a pencil beam approach to photon dose calculations in the head and neck region Radiotherapy and Oncology. ,vol. 37, pp. 74- 80 ,(1995) , 10.1016/0167-8140(95)01609-K
Anders Ahnesjö, Maria Mania Aspradakis, Dose calculations for external photon beams in radiotherapy Physics in Medicine and Biology. ,vol. 44, pp. R99- R155 ,(1999) , 10.1088/0031-9155/44/11/201
Martin J Butson, Rebecca Elferink, Tsang Cheung, Peter K N Yu, Michael Stokes, Kim You Quach, Peter Metcalfe, Verification of lung dose in an anthropomorphic phantom calculated by the collapsed cone convolution method Physics in Medicine and Biology. ,vol. 45, pp. 143- 149 ,(2000) , 10.1088/0031-9155/45/11/402
M Allahverdi, A Nisbet, D I Thwaites, An evaluation of epoxy resin phantom materials for megavoltage photon dosimetry. Physics in Medicine and Biology. ,vol. 44, pp. 1125- 1132 ,(1999) , 10.1088/0031-9155/44/5/001
Luca Cozzi, Antonella Fogliata, Francesca Buffa, Sabine Bieri, Dosimetric impact of computed tomography calibration on a commercial treatment planning system for external radiation therapy Radiotherapy and Oncology. ,vol. 48, pp. 335- 338 ,(1998) , 10.1016/S0167-8140(98)00072-3