A simple time-to-pulse-height converter for use with a pulsed accelerator

作者: F.A. Johnson

DOI: 10.1016/0029-554X(68)90504-1

关键词: Sine wavePhysicsFast pulseAnodeTransformerLinearityIntegral linearityPulse heightOptics

摘要: Abstract A TPHC is described which was designed for use with a post-acceleration deflection system operating at 3.525 MHz. The converter started by sharply differentiated pulse from the anode of PM, and stopped derived sine-wave induced in pick-up loop coupled to tuned transformer deflector. deadtime few μsec provided after every conversion. electronic resolution measured be 60 ps, determined aid circuit provides fast low rate, synchronized input sine wave. differential non-linearity as ±2% over 90% range; PHA employed this measurement had manufacturer's specified linearity 2%. integral means new oscillator method developed laboratory. Start stop pulses are independent crystal-controlled sources, curve can without reference calibrated delay lines. time calibration period deflector oscillator. comparison so made that obtained using cables been various methods. major part range least good (0.4%) employed.

参考文章(15)
C. W. Williams, J. H. Neiler, Design Considerations for Maximum Bandwidth in Transistorized Pulse Amplifiers Ire Transactions on Nuclear Science. ,vol. 9, pp. 1- 6 ,(1962) , 10.1109/TNS2.1962.4316057
M. R. Cleland, P. S. Jastram, The Velocity of Gamma-Rays in Air Physical Review. ,vol. 84, pp. 271- 273 ,(1951) , 10.1103/PHYSREV.84.271
R.E. Green, R.E. Bell, Notes on a fast time-to-amplitude converter Nuclear Instruments. ,vol. 3, pp. 127- 132 ,(1958) , 10.1016/0369-643X(58)90015-X
P. C. Simms, Fast Coincidence System Based on a Transistorized Time‐to‐Amplitude Converter Review of Scientific Instruments. ,vol. 32, pp. 894- 898 ,(1961) , 10.1063/1.1717553
W.J. Alston, J.E. Draper, A simple zero crossing discriminator Nuclear Instruments and Methods. ,vol. 35, pp. 155- 157 ,(1965) , 10.1016/0029-554X(65)90026-1
Meir Birk, Quentin A. Kerns, Thomas A. Nunamaker, Electronic Variable Delay for Tracing Characteristic Curves of Coincidence Circuits and Time‐to‐Height Converters Review of Scientific Instruments. ,vol. 34, pp. 1026- 1028 ,(1963) , 10.1063/1.1718648
W.F. Mruk, Determination of the properties of delay-line coaxial cables Nuclear Instruments and Methods. ,vol. 35, pp. 61- 66 ,(1965) , 10.1016/0029-554X(65)90007-8
W.F. Mruk, THE MEASUREMENT OF FISSION FRAGMENT TIMES OF FLIGHT Nuclear Instruments and Methods. ,vol. 34, pp. 293- 306 ,(1965) , 10.1016/0029-554X(65)90313-7
D. Ophir, Fast transistorized time to amplitude converter Nuclear Instruments and Methods. ,vol. 28, pp. 237- 241 ,(1964) , 10.1016/0029-554X(64)90428-8
F.A. Johnson, A pulse-shape-discrimination circuit of wide range and high sensitivity Nuclear Instruments and Methods. ,vol. 58, pp. 134- 142 ,(1968) , 10.1016/0029-554X(68)90039-6