An automatic, vigorous-injection assisted dispersive liquid-liquid microextraction technique for stopped-flow spectrophotometric detection of boron.

作者: Michal Alexovič , Marcin Wieczorek , Joanna Kozak , Paweł Kościelniak , Ioseph S. Balogh

DOI: 10.1016/J.TALANTA.2014.04.095

关键词: Aqueous two-phase systemDetection limitCertified reference materialsCalibrationChemistryExtraction (chemistry)ChromatographyAnalytical chemistrySolventBoronWorking range

摘要: A novel automatic vigorous-injection assisted dispersive liquid-liquid microextraction procedure based on the use of a modified single-valve sequential injection manifold (SV-SIA) was developed and applied for determination boron in water samples. The major novelties are achieving efficient by means single (250 µL, 900 µL s(-1)) extraction solvent (n-amylacetate) into aqueous phase resulting effective mixing without using after self-separation phases, as well forwarding directly to Z-flow cell (10 mm) holding coil stopped-flow spectrophotometric detection. calibration working range linear up 2.43 mg L(-1) at 426nm wavelength. limit detection, calculated 3s blank test (n=10), found be 0.003 L(-1), relative standard deviation, measured ten replicable concentrations 0.41 determined 5.6%. validation method tested certified reference material.

参考文章(52)
Ana Rita A. Nogueira, Sandra M.B. Brienza, Elias A.G. Zagatto, José Luis F. Costa Lima, Alberto N. Araújo, Multi-site detection in flow analysis Analytica Chimica Acta. ,vol. 276, pp. 121- 125 ,(1993) , 10.1016/0003-2670(93)85046-M
Deniz Yurtsever Sarica, Nusret Ertaş, Flow Injection Analysis for Boron Determination by Using Methyl Borate Generation and Flame Atomic Emission Spectrometry Turkish Journal of Chemistry. ,vol. 25, pp. 305- 310 ,(2001)
Aristidis N. Anthemidis, Constantina Mitani, Paschalia Balkatzopoulou, Paraskevas D. Tzanavaras, On-line micro-volume introduction system developed for lower density than water extraction solvent and dispersive liquid-liquid microextraction coupled with flame atomic absorption spectrometry. Analytica Chimica Acta. ,vol. 733, pp. 34- 37 ,(2012) , 10.1016/J.ACA.2012.04.015
Hideko Koshima, Hiroshi Onishi, Extraction of tetrafluoroborate with crown ethers and its application to silicate rock analysis Fresenius Journal of Analytical Chemistry. ,vol. 343, pp. 287- 291 ,(1992) , 10.1007/BF00322376
P CARRERO, A MALAVE, E ROJAS, C RONDON, Y DEPENA, J BURGUERA, M BURGUERA, On-line generation and hydrolysis of methyl borate for the spectrophotometric determination of boron in soil and plants with azomethine-H Talanta. ,vol. 68, pp. 374- 381 ,(2005) , 10.1016/J.TALANTA.2005.08.058
Pietro Lanza, Pier Luigi Buldini, Potentiometric determination of boron in silicon with an ion-selective electrode Analytica Chimica Acta. ,vol. 75, pp. 149- 157 ,(1975) , 10.1016/S0003-2670(01)81962-0
Sezgin Bakirdere, Seda Orenay, Mehmet Korkmaz, Effect of Boron on Human Health The Open Mineral Processing Journal. ,vol. 3, pp. 54- 59 ,(2010) , 10.2174/1874841401003010054