Methodical approach for the use of GC‐TOF MS for screening and confirmation of organic pollutants in environmental water

作者: Tania Portolés , Elena Pitarch , Francisco J. López , Juan V. Sancho , Félix Hernández

DOI: 10.1002/JMS.1248

关键词: Mass spectrometrySolid phase extractionTime-of-flight mass spectrometrySample preparationExtraction (chemistry)Gas chromatography–mass spectrometryChromatographyChemistryGas chromatographyAnalyteAnalytical chemistry

摘要: The potential of gas chromatography coupled to time-of-flight mass spectrometry (GC-TOF MS) for the screening organic pollutants in water was explored. After a conventional SPE step with C18 cartridges, comparison spectra available libraries together an evaluation accuracy first approach used and confirmation target analytes. However, at low analyte concentrations (i.e. below 0.1 µg/l), this procedure not feasible use application manager TargetLynx evaluated. This allows selection up five representative ions per analyte, measured high accuracy, their intensity ratio evaluation. Ion selection, extraction window concentration levels were found be critical parameters. reference compound as ‘lock mass’ also affect quality information obtained some particular cases. Full spectral acquisition data generated by TOF MS analyzer allowed investigation presence several analytes samples post-target style, without need reanalyze samples. Finally, methodical established reliable (PAHs, pesticides, octyl/nonyl phenols) real-world samples, which led satisfactory results ∼0.1 µg/l. Copyright © 2007 John Wiley & Sons, Ltd.

参考文章(27)
F Hernandez, JV Sancho, OJ Pozo, None, Critical review of the application of liquid chromatography/mass spectrometry to the determination of pesticide residues in biological samples Analytical and Bioanalytical Chemistry. ,vol. 382, pp. 934- 946 ,(2005) , 10.1007/S00216-005-3185-5
Jitka Zrostlı́ková, Jana Hajšlová, Tomáš Čajka, Evaluation of two-dimensional gas chromatography-time-of-flight mass spectrometry for the determination of multiple pesticide residues in fruit. Journal of Chromatography A. ,vol. 1019, pp. 173- 186 ,(2003) , 10.1016/S0021-9673(03)01302-5
George Perkins, Frank Pullen, Christine Thompson, Automated high resolution mass spectrometry for the synthetic chemist Journal of the American Society for Mass Spectrometry. ,vol. 10, pp. 546- 551 ,(1999) , 10.1016/S1044-0305(99)00014-8
R.B Geerdink, W.M.A Niessen, U.A.Th Brinkman, Trace-level determination of pesticides in water by means of liquid and gas chromatography Journal of Chromatography A. ,vol. 970, pp. 65- 93 ,(2002) , 10.1016/S0021-9673(02)00234-0