Imaging for Stereotactic Spine Radiotherapy: Clinical Considerations

作者: Max Dahele , Jaap D. Zindler , Esther Sanchez , Wilko F. Verbakel , Joost P.A. Kuijer

DOI: 10.1016/J.IJROBP.2011.04.039

关键词:

摘要: There is growing interest in the use of stereotactic body radiation therapy (SBRT) for spinal metastases. With need accurate target definition and conformal avoidance critical normal structures, high-quality multimodal imaging has emerged as a key component at each stage treatment process. Multidisciplinary collaboration is necessary to optimize protocols implement advances into routine patient care.

参考文章(73)
Samuel Ryu, Stephanie L. Pugh, Peter C. Gerszten, Fang-Fang Yin, Robert D. Timmerman, Ying J. Hitchcock, Benjamin Movsas, Andrew A. Kanner, Lawrence B. Berk, David S. Followill, Lisa A. Kachnic, RTOG 0631 phase 2/3 study of image guided stereotactic radiosurgery for localized (1-3) spine metastases: phase 2 results. Practical radiation oncology. ,vol. 4, pp. 76- 81 ,(2011) , 10.1016/J.PRRO.2013.05.001
GARETH J. LOUGHREY, CONOR D. COLLINS, SUSAN M. TODD, NICOLA M. BROWN, RICHARD J. JOHNSON, Magnetic Resonance Imaging in the Management of Suspected Spinal Canal Disease in Patients with Known Malignancy Clinical Radiology. ,vol. 55, pp. 849- 855 ,(2000) , 10.1053/CRAD.2000.0547
Daniel Vanel, Roberto Casadei, Marco Alberghini, Manel Razgallah, Maurizio Busacca, Ugo Albisinni, MR Imaging of Bone Metastases and Choice of Sequence: Spin Echo, In-Phase Gradient Echo, Diffusion, and Contrast Medium Seminars in Musculoskeletal Radiology. ,vol. 13, pp. 097- 103 ,(2009) , 10.1055/S-0029-1220880
Dwight E. Heron, Regiane S. Andrade, Sushil Beriwal, Ryan P. Smith, PET-CT in radiation oncology: the impact on diagnosis, treatment planning, and assessment of treatment response. American Journal of Clinical Oncology. ,vol. 31, pp. 352- 362 ,(2008) , 10.1097/COC.0B013E318162F150
Nathan White, Cooper Roddey, Ajit Shankaranarayanan, Eric Han, Dan Rettmann, Juan Santos, Josh Kuperman, Anders Dale, PROMO: Real-time prospective motion correction in MRI using image-based tracking. Magnetic Resonance in Medicine. ,vol. 63, pp. 91- 105 ,(2010) , 10.1002/MRM.22176
Stine Korreman, Coen Rasch, Helen McNair, Dirk Verellen, Uwe Oelfke, Philippe Maingon, Ben Mijnheer, Vincent Khoo, The European Society of Therapeutic Radiology and Oncology–European Institute of Radiotherapy (ESTRO–EIR) report on 3D CT-based in-room image guidance systems: A practical and technical review and guide Radiotherapy and Oncology. ,vol. 94, pp. 129- 144 ,(2010) , 10.1016/J.RADONC.2010.01.004
Samuel Ryu, Fang Fang Yin, Jack Rock, Jingeng Zhu, Archie Chu, Eduard Kagan, Lisa Rogers, Munther Ajlouni, Mark Rosenblum, Jae Ho Kim, Image-guided and intensity-modulated radiosurgery for patients with spinal metastasis. Cancer. ,vol. 97, pp. 2013- 2018 ,(2003) , 10.1002/CNCR.11296
Jean-Pierre Bissonnette, Doug Moseley, Elizabeth White, Michael Sharpe, Tom Purdie, David A. Jaffray, Quality Assurance for the Geometric Accuracy of Cone-Beam CT Guidance in Radiation Therapy International Journal of Radiation Oncology*Biology*Physics. ,vol. 71, pp. S57- S61 ,(2008) , 10.1016/J.IJROBP.2007.06.086
H.-S. Gwak, S.-M. Youn, U. Chang, D. Lee, G. Cheon, C. Rhee, K. Kim, H.-J. Kim, Usefulness of 18F-fluorodeoxyglucose PET for radiosurgery planning and response monitoring in patients with recurrent spinal metastasis Minimally Invasive Neurosurgery. ,vol. 49, pp. 127- 134 ,(2006) , 10.1055/S-2006-932181
Yongbin Zhang, Lifei Zhang, X. Ronald Zhu, Andrew K. Lee, Mark Chambers, Lei Dong, Reducing metal artifacts in cone-beam CT images by preprocessing projection data International Journal of Radiation Oncology Biology Physics. ,vol. 67, pp. 924- 932 ,(2007) , 10.1016/J.IJROBP.2006.09.045