Image Reconstruction from List-Mode Data in an Emission Tomography System Having Time-of-Flight Measurements

作者: Donald L. Snyder , David G. Politte

DOI: 10.1109/TNS.1983.4332660

关键词:

摘要: List-mode data collected in a positron-emission tomography system having time-of-flight measurements are three dimensional, but all algorithms which have been published to date operate on two-dimensional derived from these three-dimensional data. We argue this paper that the additional information present is useful for improving reconstructions of images.

参考文章(10)
N. A. Mullani, J. Gaeta, K. Yerian, W. H. Wong, R. K. Hartz, E. A. Philippe, D. Bristow, K. L. Gould, Dynamic Imaging with High Resolution Time-of-Flight PET Camera - TOFPET I IEEE Transactions on Nuclear Science. ,vol. 31, pp. 609- 613 ,(1984) , 10.1109/TNS.1984.4333329
E. A. Philippe, N. Mullani, W. Wong, R. Hartz, Real-Time Image Reconstruction for Time-of-Flight Positron Emission Tomography (TOFPET) IEEE Transactions on Nuclear Science. ,vol. 29, pp. 524- 528 ,(1982) , 10.1109/TNS.1982.4335900
J. Blaine, D. Ficke, R. Hitchens, T. Holmes, Data Acquisition Aspects of Super-PETT IEEE Transactions on Nuclear Science. ,vol. 29, pp. 544- 547 ,(1982) , 10.1109/TNS.1982.4335904
D A Ortendahl, D W Shosa, L Kaufman, R Hattner, R Herfkens, W Rowan, Resolution and contrast recovery at depth in planar nuclear images. Physics in Medicine and Biology. ,vol. 27, pp. 257- 275 ,(1982) , 10.1088/0031-9155/27/2/007
A. P. Dempster, N. M. Laird, D. B. Rubin, Maximum Likelihood from Incomplete Data Via theEMAlgorithm Journal of the Royal Statistical Society: Series B (Methodological). ,vol. 39, pp. 1- 22 ,(1977) , 10.1111/J.2517-6161.1977.TB01600.X
L. A. Shepp, Y. Vardi, Maximum Likelihood Reconstruction for Emission Tomography IEEE Transactions on Medical Imaging. ,vol. 1, pp. 113- 122 ,(1982) , 10.1109/TMI.1982.4307558
Donald L. Snyder, Lewis J. Thomas, Michel M. Ter-Pogossian, A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight Measurements IEEE Transactions on Nuclear Science. ,vol. 28, pp. 3575- 3583 ,(1981) , 10.1109/TNS.1981.4332168
Michel M. Ter-Pogossian, Nizar A. Mullani, John Hood, Carol S. Higglns, C. Michael Currie, A Multislice Positron Emission Computed Tomograph (PETT IV) Yielding Transverse and Longitudinal Images Radiology. ,vol. 128, pp. 477- 484 ,(1978) , 10.1148/128.2.477
K. Lance Gould, Nizar A. Mullani, K. Yerian, Edward A. Philippe, Wai Hoi Wong, Ross K. Hartz, DESIGN OF TOFPET: A HIGH RESOLUTION TIME-OF-FLIGHT POSITRON CAMERA. IEEE. pp. 31- 36 ,(1982)