Operation of a quadrupole ion trap mass spectrometer to achieve high mass/charge ratios

作者: Raymond E. Kaiser , R. Graham Cooks , George C. Stafford , John E.P. Syka , Philip H. Hemberger

DOI: 10.1016/0168-1176(91)85013-C

关键词:

摘要: … Performance at high mass is illustrated by recording data on CsI clusters and on … mass/charge measurements are accurate to better than 0.1% without external calibration, that a mass …

参考文章(19)
G.C. Stafford, P.E. Kelley, J.E.P. Syka, W.E. Reynolds, J.F.J. Todd, Recent improvements in and analytical applications of advanced ion trap technology International Journal of Mass Spectrometry and Ion Processes. ,vol. 60, pp. 85- 98 ,(1984) , 10.1016/0168-1176(84)80077-4
Randall D. Knight, The general form of the quadrupole ion trap potential International Journal of Mass Spectrometry and Ion Physics. ,vol. 51, pp. 127- 131 ,(1983) , 10.1016/0020-7381(83)85033-5
Joseph E. Campana, Brett I. Dunlap, Secondary ion mass spectrometry (SIMS) of metal halides. IV. The envelopes of secondary cluster ion distributions International Journal of Mass Spectrometry and Ion Processes. ,vol. 57, pp. 103- 123 ,(1984) , 10.1016/0168-1176(84)85069-7
Scott A. Mcluckey, Gary L. Glish, Keiji G. Asano, Coupling of an atmospheric-samling ion source with an ion-trap mass spectrometer Analytica Chimica Acta. ,vol. 225, pp. 25- 35 ,(1989) , 10.1016/S0003-2670(00)84591-2
Jennifer S. Brodbelt, John N. Louris, R. Graham. Cooks, CHEMICAL IONIZATION IN AN ION TRAP MASS SPECTROMETER. Analytical Chemistry. ,vol. 59, pp. 1278- 1285 ,(1987) , 10.1021/AC00136A007
Gary J. Van Berkel, Gary L. Glish, Scott A. McLuckey, Electrospray ionization combined with ion trap mass spectrometry Analytical Chemistry. ,vol. 62, pp. 1284- 1295 ,(1990) , 10.1021/AC00212A016
J. E. Campana, T. M. Barlak, R. J. Colton, J. J. DeCorpo, J. R. Wyatt, B. I. Dunlap, Effect of cluster surface energies on secondary-ion--intensity distributions from ionic crystals Physical Review Letters. ,vol. 47, pp. 1046- 1049 ,(1981) , 10.1103/PHYSREVLETT.47.1046
Raymond E. Kaiser, R. Graham Cooks, James Moss, Phillip H. Hemberger, Mass range extension in a quadrupole ion‐trap mass spectrometer Rapid Communications in Mass Spectrometry. ,vol. 3, pp. 50- 53 ,(1989) , 10.1002/RCM.1290030213
William. Aberth, Kenneth M. Straub, A. L. Burlingame, Secondary ion mass spectrometry with cesium ion primary beam and liquid target matrix for analysis of bioorganic compounds Analytical Chemistry. ,vol. 54, pp. 2029- 2034 ,(1982) , 10.1021/AC00249A028
Scott A. McLuckey, Gary L. Glish, Keiji G. Asano, Gary J. Van Berkel, Self chemical ionization in an ion trap mass spectrometer Analytical Chemistry. ,vol. 60, pp. 2312- 2314 ,(1988) , 10.1021/AC00171A033