Effect of Various Deposition Techniques, Electrode Materials and Posttreatment with Tetrabutylammonium and Tetrabutylphosphonium Salts on the Electrochemical Behavior and Stability of Various Prussian Blue Modified Electrodes

作者: Behzad Haghighi , Nafiseh Shams , Lo Gorton

DOI: 10.1002/ELAN.200703962

关键词:

摘要: The effect of various deposition techniques, electrode materials and posttreatment with tetrabutylammonium tetrabutylphosphonium salts on the electrochemical behavior stability Prussian blue (PB) modified electrodes, namely PB glassy carbon silicate-film supported PB-doped silicate ceramic electrodes using chemical is reported. Cyclic voltammetry amperometric measurements hydrogen peroxide were performed in a flow injection system while carrier phosphate buffer (pH 7.0) rate 0.8 mL min(-1) was propelled into through cell housing working as well an AgAgC.1, M KCl reference Pt auxiliary electrode. results showed that procedure, material additional chemicals can significantly alter film. Among studied those based film electropolymerized best stability. (Less)

参考文章(40)
A. Roig, J. Navarro, R. Tamarit, F. Vicente, Stability of Prussian Blue films on ITO electrodes: effect of different anions Journal of Electroanalytical Chemistry. ,vol. 360, pp. 55- 69 ,(1993) , 10.1016/0022-0728(93)87004-F
Ivanildo Luiz de MATTOS, Lo GORTON, Tautgirdas RUZGAS, Arkady A KARYAKIN, Sensor for hydrogen peroxide based on Prussian blue modified electrode : Improvement of the operational stability Analytical Sciences. ,vol. 16, pp. 795- 798 ,(2000) , 10.2116/ANALSCI.16.795
M. Troquet, J.P. Labbe, J. Pagetti, The mechanism of the inhibition of zinc corrosion in 1N HCl solution by tetraphenylphosphonium bromide Corrosion Science. ,vol. 21, pp. 101- 117 ,(1981) , 10.1016/0010-938X(81)90095-0
Kingo Itaya, Kimio Shibayama, Haruo Akahoshi, Shinobu Toshima, Prussian‐blue‐modified electrodes: An application for a stable electrochromic display device Journal of Applied Physics. ,vol. 53, pp. 804- 805 ,(1982) , 10.1063/1.329997
B.J. Feldman, O.R. Melroy, Ion flux during electrochemical charging of Prussian Blue films Journal of Electroanalytical Chemistry and Interfacial Electrochemistry. ,vol. 234, pp. 213- 227 ,(1987) , 10.1016/0022-0728(87)80173-0
Subramanian Bharathi, Ovadia Lev, Sol-gel-derived prussian blue-silicate amperometric glucose biosensor. Applied Biochemistry and Biotechnology. ,vol. 89, pp. 209- 216 ,(2000) , 10.1385/ABAB:89:2-3:209
Roger Appelqvist, György Marko-Varga, Lo Gorton, Arne Torstensson, Gillis Johansson, Enzymatic determination of glucose in a flow system by catalytic oxidation of the nicotinamide coenzyme at a modified electrode Analytica Chimica Acta. ,vol. 169, pp. 237- 247 ,(1985) , 10.1016/S0003-2670(00)86226-1