3D high-resolution contrast enhanced MRI of carotid atheroma--a technical update.

作者: Chengcheng Zhu , Umar Sadat , Andrew J. Patterson , Zhongzhao Teng , Jonathan H. Gillard

DOI: 10.1016/J.MRI.2014.01.019

关键词:

摘要: Abstract Objective Development of a fast 3D high-resolution magnetic resonance imaging (MRI) protocol for improved carotid artery plaque imaging. Methods Two patients with atherosclerosis disease underwent MRI which included time-of-flight and T 1 -weighted variable flip angle, fast-spin-echo (FSE) imaging, pre- post-intravenous gadolinium-based contrast agent administration. Results Good quality images intrinsic blood suppression were obtained post-contrast administration using FSE sequence. The burden, lipid core volume, hemorrhage volume fibrous cap thickness well determined. Conclusions MR TOF can achieve high isotropic resolution, large coverage, excellent image within short acquisition time.

参考文章(17)
Reed F. Busse, Anja C.S. Brau, Anthony Vu, Charles R. Michelich, Ersin Bayram, Richard Kijowski, Scott B. Reeder, Howard A. Rowley, Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo. Magnetic Resonance in Medicine. ,vol. 60, pp. 640- 649 ,(2008) , 10.1002/MRM.21680
Hunter R. Underhill, Thomas S. Hatsukami, Zahi A. Fayad, Valentin Fuster, Chun Yuan, MRI of carotid atherosclerosis: clinical implications and future directions Nature Reviews Cardiology. ,vol. 7, pp. 165- 173 ,(2010) , 10.1038/NRCARDIO.2009.246
Sarah M Debrey, Hua Yu, John K Lynch, Karl-Olof Lövblad, Violet L Wright, Sok-Ja D Janket, Alison E Baird, None, Diagnostic Accuracy of Magnetic Resonance Angiography for Internal Carotid Artery Disease A Systematic Review and Meta-Analysis Stroke. ,vol. 39, pp. 2237- 2248 ,(2008) , 10.1161/STROKEAHA.107.509877
Rikin A. Trivedi, Jean-Marie U-King-Im, Martin J. Graves, Jo Horsley, Martin Goddard, Peter J. Kirkpatrick, Jonathan H. Gillard, MRI-derived measurements of fibrous-cap and lipid-core thickness: the potential for identifying vulnerable carotid plaques in vivo. Neuroradiology. ,vol. 46, pp. 738- 743 ,(2004) , 10.1007/S00234-004-1247-6
Wenbo Liu, Niranjan Balu, Jie Sun, Xihai Zhao, Huijun Chen, Chun Yuan, Huilin Zhao, Jianrong Xu, Guangzhi Wang, William S. Kerwin, Segmentation of carotid plaque using multicontrast 3D gradient echo MRI. Journal of Magnetic Resonance Imaging. ,vol. 35, pp. 812- 819 ,(2012) , 10.1002/JMRI.22886
Riccardo Soverini, Giorgio Benea, Stefano Tartari, Roberto Rizzati, Riccardo Righi, Anna Deledda, Katia Capello, High-Resolution MRI of Carotid Plaque With a Neurovascular Coil and Contrast-Enhanced MR Angiography: One-Stop Shopping for the Comprehensive Assessment of Carotid Atherosclerosis American Journal of Roentgenology. ,vol. 196, pp. 1164- 1171 ,(2011) , 10.2214/AJR.10.4751
Shaoxiong Zhang, Jianming Cai, Ying Luo, Chao Han, Nayak L. Polissar, Thomas S. Hatsukami, Chun Yuan, Measurement of Carotid Wall Volume and Maximum Area with Contrast-enhanced 3D MR Imaging: Initial Observations Radiology. ,vol. 228, pp. 200- 205 ,(2003) , 10.1148/RADIOL.2281020484
Jian-Ming Cai, Thomas S. Hatsukami, Marina S. Ferguson, Randy Small, Nayak L. Polissar, Chun Yuan, Classification of Human Carotid Atherosclerotic Lesions With In Vivo Multicontrast Magnetic Resonance Imaging Circulation. ,vol. 106, pp. 1368- 1373 ,(2002) , 10.1161/01.CIR.0000028591.44554.F9
Jinnan Wang, Vasily L. Yarnykh, Chun Yuan, Enhanced image quality in black-blood MRI using the improved motion-sensitized driven-equilibrium (iMSDE) sequence. Journal of Magnetic Resonance Imaging. ,vol. 31, pp. 1256- 1263 ,(2010) , 10.1002/JMRI.22149