The Preliminary Research of Drill Guide Template Design for Pedicle Screw Placement with a Low-Cost 3D Pinter

作者: Chao Yaug Liao , Ching Jen Cheng , Wei Jhen Huang , Che Ming Cheng

DOI: 10.4028/WWW.SCIENTIFIC.NET/AMM.493.507

关键词:

摘要: The purpose of this study is illustrated the potential applying additive manufacturing (AM) technology with a low-cost three-dimensional (3D) printer on clinical applications spine surgeries. First, target vertebrae will be extracted from computed tomography (CT) images patient and converted to 3D polyhedral model. After choosing regions pedicle screws in model, optimal screw angles depths obtained without injuring spinal cord. Then, drill guide template developed by using an AM software, fabricated printer. doctor can utilize it buckle specific designed position patient, directly through hole during scoliosis surgery. These steps reduce surgical time substantially. Finally, several cases were executed verify placement accuracy templates

参考文章(8)
Amit Bandyopadhyay, Vamsi K Balla, Sheldon A Bernard, Susmita Bose, None, Micro‐Layered Manufacturing Micro-Manufacturing: Design and Manufacturing of Micro-Products. pp. 97- 158 ,(2011) , 10.1002/9781118010570.CH5
Vaibhav Bagaria, Shirish Deshpande, Darshana D. Rasalkar, Abhay Kuthe, Bhawan K. Paunipagar, Use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures. European Journal of Radiology. ,vol. 80, pp. 814- 820 ,(2011) , 10.1016/J.EJRAD.2010.10.007
Keya Mao, Yan Wang, Songhua Xiao, Zhengsheng Liu, Yonggang Zhang, Xuesong Zhang, Zheng Wang, Ning Lu, Zhu Shourong, Zhang Xifeng, Cui Geng, Liu Baowei, Clinical application of computer-designed polystyrene models in complex severe spinal deformities: a pilot study European Spine Journal. ,vol. 19, pp. 797- 802 ,(2010) , 10.1007/S00586-010-1359-0
Tao Ma, Yong-Qing Xu, Yu-Bin Cheng, Mu-Yao Jiang, Xing-Ming Xu, Le Xie, Sheng Lu, A novel computer-assisted drill guide template for thoracic pedicle screw placement: a cadaveric study Archives of Orthopaedic and Trauma Surgery. ,vol. 132, pp. 65- 72 ,(2012) , 10.1007/S00402-011-1383-5
Sheng Lu, Yong Q. Xu, William W. Lu, Guo X. Ni, Yan B. Li, Ji H. Shi, Dong P. Li, Guo P. Chen, Yu B. Chen, Yuan Z. Zhang, A novel patient-specific navigational template for cervical pedicle screw placement. Spine. ,vol. 34, ,(2009) , 10.1097/BRS.0B013E3181C09985
Jin Cheng Yang, Xiang Yang Ma, Jun Lin, Zeng Hui Wu, Kai Zhang, Qing Shui Yin, Personalised modified osteotomy using computer-aided design–rapid prototyping to correct thoracic deformities International Orthopaedics. ,vol. 35, pp. 1827- 1832 ,(2011) , 10.1007/S00264-010-1155-9
Sheng Lu, Yuan Z Zhang, Zheng Wang, Ji H Shi, Yu B Chen, Xing M Xu, Yong Q Xu, None, Accuracy and efficacy of thoracic pedicle screws in scoliosis with patient-specific drill template Medical & Biological Engineering & Computing. ,vol. 50, pp. 751- 758 ,(2012) , 10.1007/S11517-012-0900-1
GEORGE A. BROWN, KEIKHOSROW FIROOZBAKHSH, THOMAS A. DECOSTER, JOSÉ R. REYNA, MOHEB MONEIM, Rapid prototyping: the future of trauma surgery? Journal of Bone and Joint Surgery, American Volume. ,vol. 85, pp. 49- 55 ,(2003) , 10.2106/00004623-200300004-00006