Electronic bracelet for monitoring of alcohol lifestyle

作者: David Kinnamon , Anjan Panneer Selvam , Shalini Prasad , Sriram Muthukumar

DOI: 10.1109/ICSENS.2016.7808598

关键词:

摘要: We demonstrate a wearable electronic bracelet for monitoring of alcohol lifestyle through the detection ethyl glucuronide (EtG), metabolite ethanol associated with consumption, from human sweat. The device leverages disposable nanoporous polymer substrates that easily wick small volumes sweat over sensors electrodes. A gold working electrode fabricated on flexible substrate is functionalized EtG specific monocolonal antibodies using thiol based chemistry, as well potassium ferricyanide redox molecule. When exposed to in pooled sweat, and analog binding sensing results chemiresistive changes surface can be quantified square wave voltammetry (SWV). Varying doses was thus reported electronically by measuring response peak currents. Detection demonstrated range 1–100 μg/mL analog. Similar dose discrimination shown 1–10000 μg/L corresponding one or more U.S. standard drinks. Validation sensor performance done cyclic electrochemical impedance spectroscopy.

参考文章(10)
Mary K Serdula, Robert D Brewer, Cathleen Gillespie, Clark H Denny, Ali Mokdad, None, Trends in alcohol use and binge drinking, 1985-1999: results of a multi-state survey. American Journal of Preventive Medicine. ,vol. 26, pp. 294- 298 ,(2004) , 10.1016/J.AMEPRE.2003.12.017
György Inzelt, Pseudo-reference Electrodes Springer, Berlin, Heidelberg. pp. 331- 332 ,(2013) , 10.1007/978-3-642-36188-3_14
Robert B. Voas, Enhancing the use of vehicle alcohol interlocks with emerging technology Alcohol research : current reviews. ,vol. 36, pp. 81- 89 ,(2014)
Ruth A Shults, Gwen Bergen, Rose Ann Rudd, Vital signs: alcohol-impaired driving among adults--United States, 2010 Morbidity and Mortality Weekly Report (MMWR). ,vol. 60, ,(2011)
Claude Schummer, Brice M R Appenzeller, Robert Wennig, Quantitative determination of ethyl glucuronide in sweat. Therapeutic Drug Monitoring. ,vol. 30, pp. 536- 539 ,(2008) , 10.1097/FTD.0B013E318180C83D
V.A Ramchandani, W.F Bosron, T.K Li, Research advances in ethanol metabolism. Pathologie Biologie. ,vol. 49, pp. 676- 682 ,(2001) , 10.1016/S0369-8114(01)00232-2
Anjan Panneer Selvam, K. M. Vattipalli, S. Prasad, Design of a high sensitive non-faradaic impedimetric sensor international conference of the ieee engineering in medicine and biology society. ,vol. 2012, pp. 3251- 3254 ,(2012) , 10.1109/EMBC.2012.6346658
Gudrun Høiseth, Borghild Yttredal, Ritva Karinen, Hallvard Gjerde, Jørg Mørland, Asbjørg Christophersen, Ethyl Glucuronide Concentrations in Oral Fluid, Blood, and Urine After Volunteers Drank 0.5 and 1.0 g/kg Doses of Ethanol Journal of Analytical Toxicology. ,vol. 34, pp. 319- 324 ,(2010) , 10.1093/JAT/34.6.319
By Kasem K. Kasem, Stephanie Jones, Platinum as a Reference Electrode in Electrochemical Measurements Platinum Metals Review. ,vol. 52, pp. 100- 106 ,(2008) , 10.1595/147106708X297855
Anjan Panneer Selvam, Sriram Muthukumar, Vikramshankar Kamakoti, Shalini Prasad, A wearable biochemical sensor for monitoring alcohol consumption lifestyle through Ethyl glucuronide (EtG) detection in human sweat Scientific Reports. ,vol. 6, pp. 23111- 23111 ,(2016) , 10.1038/SREP23111