作者: Carl-Olof Werner , Per Ohlin , Dan Elmqvist
DOI: 10.3109/17453678508994358
关键词:
摘要: The pressure between the ulnar nerve and arcade bridging two heads of flexor carpi ulnaris muscle was recorded peroperatively in ten patients with electrophysiologically confirmed neuropathy at elbow. At rest, elbow extended, pressures ranged from 0 to 19 mm Hg but increased flexion during isometric contraction maximal values above 200 Hg.