Compliant design of artificial graft: Compliance determination by new digital X-ray imaging system-based method

作者: Hiromichi Sonoda , Shin-Ichi Urayama , Keiichi Takamizawa , Yasuhide Nakayama , Chikao Uyama

DOI: 10.1002/JBM.10055

关键词:

摘要: The development of an artificial graft requires formulation biomechanical design criteria. compliance artifical grafts, based on the intraluminal pressure-internal diameter (Pi-Di) relationship, was measured by a novel method using digital X-ray imaging system coupled with edge detection algorithm and pressure transducer. Pi-Di values were obtained from angiographic images under continuous inflation canine femoral artery anastomosed expanded poly(tetrafluoroethylene) (ePTFE) vascular as model vessel pressurized contrast medium. Di at Pi NIH Image software specially programmed for entropy filter method, which enables phantoms images, determined. relationships showed “J-shape” curve artery, steeper line very low pressure-dependent distensibility ePTFE graft, intermediate anastomosis protion. two indices compliance, stiffness parameter (β value) (Cd), both calculated relationships, 10.6 6.8%/mmHg × 10-2 164 0.51%/mmHg ePTFE, 14.4 5.5%/mmHg portion, respectively. This can measure any portions sampling in single experiment real-time basis high accuracy, compared conventional methods, even cases intimal thickening and/or connective tissues-adhered vessels, may serve to provide information compliant criteria tissue-engineered graft. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 60: 191–195,

参考文章(23)
CHIKAO UYAMA, YASUSI KITA, SHUNSUKE MATSUSITA, Optimal sampling interval and edge detection algorithm for measurement of blood vessel diameter on a cineangiogram. Investigative Radiology. ,vol. 28, pp. 1128- 1132 ,(1993) , 10.1097/00004424-199312000-00008
K. Hayashi, N. Matsuguchi, K. Uenoyama, T. Kanemaru, Y. Sugioka, Evaluation of metal implants coated with several types of ceramics as biomaterials Journal of Biomedical Materials Research. ,vol. 23, pp. 1247- 1259 ,(1989) , 10.1002/JBM.820231103
Philip B. Dobrin, Raul Mirande, Steven Kang, Quan Sheng Dong, Robert Mrkvicka, Mechanics of end-to-end artery-to-PTFE graft anastomoses. Annals of Vascular Surgery. ,vol. 12, pp. 317- 323 ,(1998) , 10.1007/S100169900161
Kozaburo Hayashi, Takao Nakamura, Material test system for the evaluation of mechanical properties of biomaterials Journal of Biomedical Materials Research. ,vol. 19, pp. 133- 144 ,(1985) , 10.1002/JBM.820190204
Matthew W. Weston, Kyehan Rhee, John M. Tarbell, Compliance and diameter mismatch affect the wall shear rate distribution near an end-to-end anastomosis Journal of Biomechanics. ,vol. 29, pp. 187- 198 ,(1996) , 10.1016/0021-9290(95)00028-3
Akira Shiozaki, Edge extraction using entropy operator Graphical Models \/graphical Models and Image Processing \/computer Vision, Graphics, and Image Processing. ,vol. 36, pp. 1- 9 ,(1986) , 10.1016/S0734-189X(86)80025-1
Jonathan E. Hasson, Joseph Megerman, William M. Abbott, Increased compliance near vascular anastomoses. Journal of Vascular Surgery. ,vol. 2, pp. 419- 423 ,(1985) , 10.1016/0741-5214(85)90095-3
William M. Abbott, Joseph Megerman, Jonathan E. Hasson, Gilbert L'Italien, David F. Warnock, Effect of compliance mismatch on vascular graft patency Journal of Vascular Surgery. ,vol. 5, pp. 376- 382 ,(1987) , 10.1016/0741-5214(87)90148-0
Stanley R. Klein, Effect of Suture Technique on Arterial Anastomotic Compliance Archives of Surgery. ,vol. 117, pp. 45- 47 ,(1982) , 10.1001/ARCHSURG.1982.01380250027006
Hiromichi Sonoda, Keiichi Takamizawa, Yasuhide Nakayama, Hisataka Yasui, Takehisa Matsuda, Small‐diameter compliant arterial graft prosthesis: Design concept of coaxial double tubular graft and its fabrication Journal of Biomedical Materials Research. ,vol. 55, pp. 266- 276 ,(2001) , 10.1002/1097-4636(20010605)55:3<266::AID-JBM1014>3.0.CO;2-C