摘要: Cardiopulmonary bypass (CPB) represents one of the most important technical innovations in healthcare history, yet systemic responses to CPB remain a fundamentally unresolved problem. Study blood–biomaterial interaction and development biocompatible materials is intimately related efforts optimize patient outcome following CPB. This article reviews design biomaterial surfaces that have been introduced into clinical practice an attempt ameliorate detrimental consequences CPB, contrasting actual improvements benefits achieved against those predicted on basis theory vitro testing. Some discussion underlying mechanisms action as presently understood provided current limitations biomaterial-dependent strategies improve are addressed.

参考文章(92)
Claude F. Mondiere, Extracorporeal circulation pump ,(2000)
Noriyuki Tabuchi, Jacob de Haan, Piet W. Boonstra, Willem van Oeveren, Activation of fibrinolysis in the pericardial cavity during cardiopulmonary bypass The Journal of Thoracic and Cardiovascular Surgery. ,vol. 106, pp. 828- 833 ,(1993) , 10.1016/S0022-5223(19)34036-X
Mark J. Walport, Complement. Second of two parts. The New England Journal of Medicine. ,vol. 344, pp. 1140- 1144 ,(2001) , 10.1056/NEJM200104123441506
John B. Steinberg, David P. Kapelanski, John D. Olson, John M. Weiler, Cytokine and complement levels in patients undergoing cardiopulmonary bypass. The Journal of Thoracic and Cardiovascular Surgery. ,vol. 106, pp. 1008- 1016 ,(1993) , 10.1016/S0022-5223(19)33971-6
Baier Re, The role of surface energy in thrombogenesis. Bulletin of the New York Academy of Medicine. ,vol. 48, pp. 257- 272 ,(1972)
Mark J. Walport, Complement. First of two parts. The New England Journal of Medicine. ,vol. 344, pp. 1058- 1066 ,(2001) , 10.1056/NEJM200104053441406
CR Wildevuur, PG Jansen, PD Bezemer, DJ Kuik, L Eijsman, P Bruins, AP De Jong, FW Van Hardevelt, JD Biervliet, JM Hasenkam, HH Kure, L Knudsen, L Bellaiche, P Ahlburg, DY Loisance, C Baufreton, P Le Besnerais, G Bajan, Amine Matta, Michel Van Dyck, M Th Renotte, A Ponlot-Lois, Philippe Baele, EA McGovern, E Ahlvin, None, Clinical evaluation of Duraflo? II heparin treated extracorporeal circulation circuits (2nd version) the European working group on heparin coated extracorporeal circulation circuits European Journal of Cardio-Thoracic Surgery. ,vol. 11, pp. 616- 623 ,(1997) , 10.1016/S1010-7940(96)01122-0