Real-time Capillary-level Microchannel Flow Analysis Using a Full-pixel Frame-straddling Micro-PIV System

作者: Idaku Ishii , Tadayoshi Aoyama

DOI: 10.1007/978-4-431-55297-0_3

关键词:

摘要: We develop a high throughput microscopic particle image velocimetry system that can compute flow vectors of 512 × pixels in real time at 500 fps for fast microchannel flow. To many speed, gradient-based optical method is accelerated by calculating integral images product sums brightness gradients and implementing them as parallel processes on GPU-based frame-straddling high-frame-rate (HFR) vision system. Thus, the HFR system, having two cameras with delay function, simultaneously hundreds millions second, assuming small displacement between frames submillisecond delay. conducted real-time measurement experiments to quantify capillary-level microfluidic chip 7-μm-width channels, verified performance our long-term blood analysis.

参考文章(18)
L. R. Saetran, M. M. Mielnik, Micro particle image velocimetry : an overview Turbulence : international journal. ,vol. 10, pp. 83- 90 ,(2004)
H Klank, G Goranovi , J P Kutter, H Gjelstrup, J Michelsen, C H Westergaard, PIV measurements in a microfluidic 3D-sheathing structure with three-dimensional flow behaviour Journal of Micromechanics and Microengineering. ,vol. 12, pp. 862- 869 ,(2002) , 10.1088/0960-1317/12/6/318
K. V. Sharp, R. J. Adrian, Transition from laminar to turbulent flow in liquid filled microtubes Experiments in Fluids. ,vol. 36, pp. 741- 747 ,(2004) , 10.1007/S00348-003-0753-3
Guk Bae Kim, Sang Joon Lee, X-ray PIV measurements of blood flows without tracer particles Experiments in Fluids. ,vol. 41, pp. 195- 200 ,(2006) , 10.1007/S00348-006-0147-4
Peter Vennemann, Kenneth T. Kiger, Ralph Lindken, Bianca C.W. Groenendijk, Sandra Stekelenburg-de Vos, Timo L.M. ten Hagen, Nicolette T.C. Ursem, Rob E. Poelmann, Jerry Westerweel, Beerend P. Hierck, In vivo micro particle image velocimetry measurements of blood-plasma in the embryonic avian heart. Journal of Biomechanics. ,vol. 39, pp. 1191- 1200 ,(2006) , 10.1016/J.JBIOMECH.2005.03.015
Motofumi Kobatake, Takeshi Takaki, Idaku Ishii, A real-time micro-PIV system using frame-straddling high-speed vision international conference on robotics and automation. pp. 397- 402 ,(2012) , 10.1109/ICRA.2012.6224821
Yasuhiko Sugii, Shigeru Nishio, Koji Okamoto, In vivo PIV measurement of red blood cell velocity field in microvessels considering mesentery motion. Physiological Measurement. ,vol. 23, pp. 403- 416 ,(2002) , 10.1088/0967-3334/23/2/315
Yasuhiko Sugii, Shigeru Nishio, Taketoshi Okuno, Koji Okamoto, A highly accurate iterative PIV technique using a gradient method Measurement Science and Technology. ,vol. 11, pp. 1666- 1673 ,(2000) , 10.1088/0957-0233/11/12/303
Idaku Ishii, Tetsuro Tatebe, Qingyi Gu, Yuta Moriue, Takeshi Takaki, Kenji Tajima, 2000 fps real-time vision system with high-frame-rate video recording international conference on robotics and automation. pp. 1536- 1541 ,(2010) , 10.1109/ROBOT.2010.5509731
Yuji Kikuchi, Kazuo Sato, Yoshinori Mizuguchi, Modified cell-flow microchannels in a single-crystal silicon substrate and flow behavior of blood cells. Microvascular Research. ,vol. 47, pp. 126- 139 ,(1994) , 10.1006/MVRE.1994.1008